3 Phase Double Conversion Transformerless Online UPS Power Supply 10kVA - 80kVA with PF0.9 Output

Product Details
Customization: Available
Phase: Three Phase
Type: On-line
Still deciding? Get samples of US$ 650/Piece
Request Sample
Diamond Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Plant Area
>2000 square meters
Management System Certification
ISO 9001, ISO 14001
  • 3 Phase Double Conversion Transformerless Online UPS Power Supply 10kVA - 80kVA with PF0.9 Output
  • 3 Phase Double Conversion Transformerless Online UPS Power Supply 10kVA - 80kVA with PF0.9 Output
  • 3 Phase Double Conversion Transformerless Online UPS Power Supply 10kVA - 80kVA with PF0.9 Output
Find Similar Products

Basic Info.

Model NO.
33Q10K-80K
Application
Communication
Classification
Lighting/Power
Standby Time
Long-acting Machine
Standby UPS
Sine Wave Output UPS
Output Capacity
Medium Type
Equipment Mode
Decentralized
Transfer Time
Zero
Current Crest Ratio
3:1 (Max)
Nominal Voltage
3 X 400 VAC (3pH+N)
Transport Package
Cartons & Wooden Pallet
Specification
CE & ISO Certificate
Trademark
UPSEN
Origin
China
HS Code
8504402000
Production Capacity
50, 000PCS/Month

Product Description

3 phases UPS  power supply 10KVA-80KVA 0.8 Output
High Frequency Online UPS Queen Star Plus Strar Series 33Q10K-80K(3Ph in/3Ph out)

 
 
Key Features   
1:Output power factor 0.9  
2:SNMP/USB/RS-232 communications
3:Emergency power off function (EPO) 
4:True double-conversion on line UPS
5:Programmable power management outlets
6:Equipped with maintenance bypass switch
7:DSP technology guarantees high performance 
8:Adjustable charging current via LCD or software 
9:DSP Double-Conversion On-line Sine wave Design 
10:LCD Display with Advanced Monitoring for Easy UPS Management 
11:Powerful background software for parameters configuration and online updating
12:Configurable switching time from battery mode to mains mode when mains power is restored, reducing the impact on power grid or generator

 
Technical Specification:
Index 33Q 10KL 33Q 20KL 33Q 30KL 33Q 40KL  33Q 60KL  33Q 80KL Comments
Input
Input voltage
Rated voltage 380VAC/220VAC 380VAC  
Phase three phase with ground  
Turn on 
voltage range
(120±5~274±5)VAC (207±9~475±9)
VAC
 
Bypass 
voltage range
(60±5~300±5)VAC (105±9~518±9)
VAC
Could be 
adjusted 
by software.
Bypass 
low loss
60VAC~220VAC(default 60VAC) 105VAC~380VAC
(default 105VAC)
 
Bypass
 low comeback
Low loss +5VAC Low loss 
+17VAC
 
Bypass 
high loss
220VAC~300VAC(default 300VAC) 380VAC~475VAC
(default 475VAC)
 
Bypass 
high comeback
High loss -5VAC High loss -17VAC  
Line low loss
comeback
(120±5) VAC /(140±5) VAC (207±9) VAC 
(242±9) VAC
load≤50%
(140±5) VAC /(160±5) VAC (242±9) VAC
(276±9) VAC
50%≤90%
(160±5) VAC /(175±5) VAC (276±9) VAC
(302±9) VAC
load>90%
Line high loss
comeback
(275±5)VAC/(260±5)VAC (475±9)VAC
(449±9)VAC
 
Input frequency
Rated 
frequency
50Hz  
Frequency 
low loss
(40~49) ±0.2Hz(default:46Hz) Could be 
adjusted
 by software.
Frequency 
low comeback
Frequency low loss +0.5Hz
Frequency 
high loss
(51~60)±0.2Hz(default:54Hz)
Frequency 
high comeback
Frequency high loss -0.5Hz
Input power factor
Could be 
adjusted 
by software.
> 0.99 33Q 10-40KL:
220VAC,full R load
33Q 60-80KL: 
380VAC,full R load
Generator  Support generator input Generator rating
≥2*UPS rating
Input current
Rated current  14A 28A 42A 67A 80A 105A  
Input THDI <= 10%  
Output protection
Rating 
protection
32A 
Breaker
50A 
Breaker
60A 
Breaker
80A 
Breaker
100A 
Breaker
125A 
Breaker
 
Output power
VA/watt 10KVA/9KW 20KVA/18KW 30KVA/27KW 40KVA/36KW 60KVA/
54KW
80KVA/
72KW
 
Rated voltage 220VAC 380VAC Sine wave
Voltage range 200/208/220
/230/240VAC
345/359/380
/397/415 VAC
33Q 10-40KL: 
Could be 
adjusted 
by software. 
10% derating 
for 
208VAC
/200VAC.
33Q 60-80KL: 
Could be 
adjusted 
by software. 
10% derating 
for 345VAC
/359VAC.
Voltage regulation ±1%  
Voltage distortion ≤5% ≤10% Full RCD load
≤3% Full R load
DC offset ≤200mV  
Transient response ≤9% R load 
0%~100%~0%
  ≤6% R load 20%
~100%~20%
Transient recovery ≤60ms voltage recovery to 90% Full RCD load
Bypass output 
before turn-on
YES  
Crest ration 3:1  
Output frequency range
Normal mode 1,Same as input frequency(46Hz~54Hz)
2,50Hz(Input frequency>54Hz or Input frequency<46Hz)
 
Battery mode (50±0.1) Hz  
Slew rate 1 Hz/Sec  
Efficiency
Normal  mode > 93% > 90%  
Battery mode > 90% > 90%  
Overload
Normal mode
battery mode 
Overload warning only 105%±5%≤load
1min,then transfer to bypass and alarm. 105%±5%<
load≤125%±5%
30S,then transfer to bypass and alarm. 125%±5%<
load≤150%±5%
300mS, then transfer to bypass and alarm. load>150%±5%
Automatically
 retransfer
YES  
Short protection
Normal
battery mode
YES  
Transfer time
Normal to 
battery mode
0mS  
Battery to 
normal mode
0mS  
Normal to 
bypass mode
<4mS 0mS  
Bypass to 
normal mode
<4mS 0mS  
Battery and charger
Battery
Rated voltage 192VDC 240VDC 192VDC*2 192VDC*2 480VDC  
Type/Rating            
Battery 
quantity
16 20 16*2 16*2 40  
Backup time            
Protection
Low alarm voltage 
comeback voltage
(180.8V±4V)/ (188.8V±4V) (226V±4V)/ (236V±4V) (180.8V±4V)
(188.8V±4V)
(226V±4V)/ (236V±4V) (452V±4V)
(472V±4V)
33Q 30KL 
use two 
Shutdown voltage
comeback voltage
160V±4V/
168V±4V
(200V±4V)/ (210V±4V) 160V±4V/
168V±4V
(200V±4V)/ (210V±4V) (400V±4V)
(420V±4V)
 
DC protection
Overcharge 
protection
comeback voltage
(249.6V±4V)
(216V±4V)
(312V±4V) (270V±4V) (249.6V±4V)
(216V±4V)
(312V±4V) (270V±4V) (624V±4V) 
(540V±4V)
 
Leakage current < 500uA  
Over 
discharge
 protection
14.5h   Could be 
set by software
Battery test
Battery weak YES  
Battery fault YES  
Charger
Output voltage (219.2±3)VDC (277±3)VDC (219.2±3)VDC (277±3)VDC (554±3)VDC  
Charge time Depends on the external battery capacity  
Charge current 7.5A 6A 5A 4A 10A  
Interface
Alarm silence YES  
DC power 
turn-on
YES  
Automatically
 retransfer
YES  
Audio alarm
Battery mode Beep/4s  
Battery low
charger fault
Beep/1s  
UPS fault Continue beep  
Overload Beep/1s  
Bypass mode Beep/2Min  
L/N inverse Beep/2Min  
Communication
RS232 interface YES  
Intelligent slot YES  
Monitor software Appending with UPS  
Cooling
Force air cooling  
Display
LCD/LED displays UPS status
Environment
Work 
temperature
0ºC~40ºC  
Altitude <1000m  
Audible
 noise
≤60dB  
Storage 
temperature
-15ºC~45ºC  
Work humidity 20%~95%  
Standard
EMS
ESD IEC61000-4-2 Level4
RS IEC61000-4-3 Level3
EFT IEC61000-4-4 Level4
Surge IEC61000-4-5 Level4
EMI
Conducted EN55022 Class A
Radiated EN55022 Class A
Safety
Safety GB4943-2001/IEC62040-1  
Machinery features
Size
Outline dimension and net weight
L*W*H (mm) 710*260*717 840*515*1135  
Net weight(Kg) 45/93 50/98     195 208  
Optional functions
60Hz     Optional Set by software
Converter mode     Optional Set by software
ECO Optional Optional Available and 
set by software
EPO Optional Optional  
LCD display Optional    

Competitive Advantages:

1: Three Years' warranty for Online UPS, and 1% free UPS or 2% free PCB Boards
2: Good after-sales service, we will be full responsible for any faults caused by our side
3: Professional experience in power field more than 10 years
4: Professional technical support before and after sales                                              
5: Timely response, fast delivery time and flexible operations to satisfy any customers' special requests.   
6: Free OEM & ODM Service                                       
7: Competitive price, quality and mature products

Company Details
3 Phase Double Conversion Transformerless Online UPS Power Supply 10kVA - 80kVA with PF0.9 Output3 Phase Double Conversion Transformerless Online UPS Power Supply 10kVA - 80kVA with PF0.9 Output3 Phase Double Conversion Transformerless Online UPS Power Supply 10kVA - 80kVA with PF0.9 Output3 Phase Double Conversion Transformerless Online UPS Power Supply 10kVA - 80kVA with PF0.9 Output


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier