Solar Inverter Product Description
Off Grid Solar Inverter with Microprocessor control and High efficiency
1: Pure sine wave output (THD< 3%)
2: Build in MPPT solar charge controller 40A or 50A
3: Ups mode and solar inverter mode for your select by switch
Key Features
- AC Charging current 0-35A
- Can choose different types of batteries
- High-low voltage protection
- Against overload, short-circuit Protection
- Over voltage, battery reverse connection(optional)
- Under-voltage and over-temperature protection
- Selectable battery priority or utility priority
- Have UPS function and AC charger function
- AC Grid priority&battery priority working mode are selectable
- AC Grid mode: AC Bypass supplies load when AC is normal, battery invert AC Supplies load when AC is Off
- Battery priority: Battery invert supplies load when battery get full-charged; AC Bypass supplies load When battery low and at the meantime battery get charged from solar controller. It transfers back to
- Battery invert mode when battery gel full charged. It males full use of solar energy and saves electricity.
Model |
W1000 So |
W1500 So |
W2000 So |
W3000 So |
W4000 So |
W5000 So |
W6000 So |
W8K So |
W10K So |
W12K So |
Input |
Rated capacity |
1000W |
1500W |
2000W |
3000W |
4000W |
5000W |
6000W |
8KW |
10KW |
12KW |
peak power |
3000W |
4500W |
6000W |
9000W |
12000W |
15000W |
18000W |
24KW |
30KW |
36KW |
Commercial Power range(VAC) |
110VAC:73~137 120VAC:80~150 |
220VAC:145~275 230VAC:152~288 240VAC:158~300 |
Mains input frequency range |
45-65HZ |
Battery |
DC Voltage |
12 VDC / 24VDC / 48VDC |
48VDC |
48VDC / 96VDC |
96Vdc |
DC input voltage range |
12VDC:10.5-15VDC 24VDC:21-30VDC 48VDC:42-60VDC 96VDC:84-120VDC |
Charger |
AC charging |
0A-35A (set on LCD Panel) |
Output |
Capable of starting electric motor |
0.5HP |
1HP |
1.5HP |
2HP |
3HP |
AVR voltage range (VAC) |
110 / 120 / 220 / 230 / 240±10%(Auto-sensing) |
Battery over voltage protection |
12VDC:16.7VDC 24VDC:33.4V 48VDC:66.8V 96VDC:134V |
Battery over voltage alarm |
12VDC:15VDC 24VDC:30V 48VDC:60V 96VDC:120V |
Battery under voltage protection |
12VDC:10.5VDC 24VDC:21V 48VDC:42V 96VDC:84V |
Battery low voltage protection |
12VDC:10VDC 24VDC:20V 48VDC:40V 96VDC:80V |
Transfer time |
Typical:5ms(Including detection time) |
Temperature protection |
≥85ºC alarm ≥90ºC machine shut off |
overload |
IPS automatically shut down if overload exceeds 120% of normal value for 10 seconds, IPS automatically resume work if overload comes to rated load. |
Waveform |
Pure sine wave |
Frequency |
Commercial power supply: shared frequency with the commercial inversion state:60/50±0.5 |
Output frequency range |
Tracking automatically |
(electric supply mode) |
Solar MPPT Controller |
MPPT Controller |
30A |
60A |
60A or 100A |
100A |
Max PV Input Power |
360W / 720W / 1440W |
48Vdc: 2880W / 96Vdc: 5760W |
48Vdc:2880W / 4800W |
9600W |
/96Vdc:5760W / 9600W |
Max PV Input Open Circuit Voltage (Voc) |
12/24/48Vdc Max: 190Vdc; 96Vdc Max 230Vdc |
Mppt Working Voltage Range |
12V: 20-80Vdc, 24: 37-105Vdc, 48V: 72-160Vdc, 96V: 144-230Vdc |
Temperature |
Operating Temperature |
0ºC~70ºC |
Thermal method |
Cooling fan in intelligent control≤42ºC fan rotates slowly to ≥45ºC fan rotates fast |
Appearance |
External Size(mm) (L*W*H) |
460*230*200mm |
650*270*200mm |
763*315*248mm |
Gross Size(mm) (L*W*H) |
530*330*255mm |
740*350*275mm |
840*405*320mm |
Net weight(kg) |
17 |
21 |
22 |
29 |
37 |
39 |
43 |
60 |
63 |
65 |
Gross weight(kg) |
19 |
22 |
24 |
31 |
40 |
32 |
45 |
64 |
66 |
68 |