LCD home use double conversion online ups with 220/230/240Vac
Model: High Frequency Online UPS Queen Star Series 6-20 Kva (1ph in/1ph out)
Key Features:
1:True N+1 Redundancy
2:Precision Output Voltage Regulation
3:DSP Double-Conversion On-line Sinewave Design
4:Input Power Factor Correction
5:Low initial investment and flexible for future expansion
6:High efficiency IGBT (insulated gate bipolar transistor) inverter technology
7:Easy to Install & Easy to Operate & Easy to Solve
8:Superior Brownout, Surge & Transient Protection
9:Output short circuit protection by using all digital technology
10:LCD Display with Advanced Monitoring for Easy UPS Management
11:Battery Priority Mode, Designates the Inverter-Preferred UPS Configuration
12:Unique low ripple charger prevent battery charing from overheating, prolong the battery life
13:Sensitive peak current detection and protection to make UPS can supply nonlinear load high ability in resisting cold load impact,
Applications
Home, Office, Computer, Data Room, Communication,Precision instrument,Commercial facility,Intelligent equipment Server, network devices, ATM, Bank System,CCTV, Security System, Alarm System etc.
Technical Specification
Queen Star Series Q6K-20Kva |
|
|
|
Model |
Q6K |
Q6KL |
Q10K |
Q10KL |
31Q10KL |
31Q15KL |
31Q20KL |
Capacity |
6KVA/4800W |
10KVA/8000W |
15KVA/12KW |
20KVA/16KW |
Input |
Nominal Voltage |
220/230/240Vac |
380/400/415Vac |
Voltage Range |
176~276Vac (1P2W+G) |
304~478Vac (3P4W+G) |
Current |
31A (max) |
50A (max) |
50A (max) |
75A (max) |
100A (max) |
Frequency |
46~54Hz/56~64Hz |
Power Factor |
≥0.99 |
Output |
Voltage |
220/230/240± 2%Vac (1P2W+G) |
Frequency |
50/60Hz(adjustable) 50/60Hz± 5% (Line mode)
50/60Hz ± 0.05Hz ( Battery mode) |
Current |
27.3A |
45A |
68A |
91A |
Power Factor |
0.8lag |
Waveform |
Pure Sine Wave |
Waveform Distortion |
Line load <2% |
Line load <3% |
Back-up Time |
Full Load |
≥7′ |
Depends on external batteries bank's Capacity |
≥5′ |
Depends on external batteries bank's Capacity |
Half Load |
≥20′ |
≥13′ |
Battery Nominal Voltage |
192/240Vdc |
Transfer Time |
0ms |
Overload Capacity |
>105% 1min, >120% 30s transfer to bypass, shut down in 1min |
Communication |
SNMP,RS-232,USB+Intelligent Slot |
Operating Environment |
Temperature |
0C~40ºC |
Humidity |
15%~90% |
Dimension |
Width (mm) |
260 |
260 |
260 |
260 |
260 |
Depth (mm) |
560 |
533 |
560 |
533 |
560 |
Height (mm) |
717 |
501 |
717 |
501 |
717 |
Net Weight(Kg) |
68 |
18 |
70 |
20 |
28 |
30 |
30 |
*Specification are subject to change without prior notice |