• Rack Mountable Online UPS for Servers with 2u 3u 5u
  • Rack Mountable Online UPS for Servers with 2u 3u 5u
  • Rack Mountable Online UPS for Servers with 2u 3u 5u
  • Rack Mountable Online UPS for Servers with 2u 3u 5u

Rack Mountable Online UPS for Servers with 2u 3u 5u

Phase: Single Phase
Type: On-line
Protection: Overvoltage
Application: Computer, PC, Server, Data Room
Classification: Lighting/Power
Standby Time: Both
Samples:
US$ 200/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
Rack Mount Plus Star Series
Standby UPS
Sine Wave Output UPS
Output Capacity
Medium Type
Brand
Upsen
Display
Digital LCD Display
Tech
True Online Double Conversion
Output Power Factor
0.8
Transport Package
Cartons & Wooden Pallet
Specification
CE & ISO Certificate
Trademark
UPSEN
Origin
China
HS Code
8504402000
Production Capacity
50, 000PCS/Month

Product Description

Rack Mountable Online UPS for Servers with 2u 3u 5u

LCD Rack UPS Quick Read
1: Rack UPS with 19" Design 2U 3U 5U Height
2: Online UPS 1000VA 2000VA 3000VA Standard model combined with internal UPS batteries
3: Rack Mounted UPS with True Double Conversion Tech
4: Rack Mountable Online UPS with single Phase 220V 230V 240Vac or 110V 120Vac Input and Output
5: UPS with RS232, USB, SNMP , RJ45, RJ11 Port

Rack Mountable UPS Key Features
True double-conversion
Microprocessor control optimizes reliability
Output power factor correction
Wide input voltage range(110-300VAC)
Converter mode available
ECO mode for energy saving only available for 1-3KVA models
Generator compatible
Adjustable charging current via LCD or software(1A-6A)
Emergency power off function(EPO) only available for 6K/10K models
Comprehensive display allows easy monitoring access of  UPS status            

Rack UPS Applications
RM Plus Series 1KVA~10KVA High Frequency Rack Mount Online UPS is specially designed for servers, 
data-enter critical network devices,sensitive electronic equipment, telecom, bank, hospital, bureau, traffic, 
public security, ATM and so on.
 
Technical Specifcation
 
Model RM1K (L) Plus RM2K (L) Plus RM3K (L) Plus RM6K (L) Plus RM10K (L) Plus
Capacity 1KVA/800W 2KVA/1600W 3KVA/2400W 6KVA/4800W 10KVA/8000W
Input Nominal Voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC 208/220/230/240VAC
Voltage Range 55-145VAC or 110-300VAC at 50% load                                                 85-140VAC or 160-280VAC at 100% load 110-300VAC±3%  at 50% load                                                176-300VAC±3% at 100% load
Frequency 40-60Hz / 50-70Hz 40-60Hz/50-70Hz
Power Factor 0.99
Output Voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC 208/220/230/240VAC
Voltage Regulation ±1%
Frequency Range (Synchronized Range) 47-53HZ or 57-63HZ 46-54HZ or 56-64HZ
Frequency Range        (Batt. Mode) 50HZ±0.25HZ or 60HZ±0.3HZ  50HZ±0.1HZ or 60HZ±0.1HZ 
Current Crest Ratio 3:1
Harmonic Distortion ≤3% THD(Linear load)  ≤6% THD(Non-linear load)   ≤3% THD(Linear load)  ≤6% THD(Non-linear load)  
Transfer Time 0ms
Wave Form Pure Sinewave
Efficiency AC Mode 88% 89% 90% 89% 90%
 Battery Mode 83% 87% 88% 88% 89%
Battery    (Standard Model) Battery Type 12V9AH 12V9AH 12V9AH 12V7AH 12V9AH
Numbers 2PCS 4PCS 6PCS 16PCS 16PCS
Typical Recharge Time 4 hours recover to 90% capacity 9 hours recover to 90% capacity
Charging Current 1A Default:1.0 A ±  10%,           Max.:2.0A ±  10%
Charging Voltage 27.4VDC ± 1% 54.7 VDC ±1% 82.1 VDC ±1% 218.4 VDC ±  1%
Battery         (Long-run Model) Battery Type Depending on the capacity of external batteries
Numbers 3 6 8 16-20** (adjustable)
Charging Current 1.0A/2.0A/4.0A/6.0 A Default:4.0 A ±  10%,                   Max.:6.0A ± 10%
Charging Voltage 41.0VDC ± 1% 82.1 VDC ±1% 109.4VDC ±1% 273 VDC ±  1% (based on 20 pcs batteries)
Indicators LCD Panel UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
Alarm Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continously sounding
Physical (Standatd Model) Dimension,D*W*H (mm) 310*438*88 (2U) 410*438*88         (2U) 630*438*88 UPS Unit:500*438*88(2U) Battery pack:668*438*88(2U) UPS Unit:580*438*133(3U)            Battery pack:668*438*88(2U)
Net Weight(kgs) 12 19 29.3 UPS Unit:15            Battery Pack:40 UPS Unit:18                   Battery Pack:48
Physical (Long-run Model) Dimension,D*W*H       (mm) 310*438*88   (2U) 410*438*88(2U) 500*438*88  (2U) 580*438*133 (3U)
Net Weight(kgs) 9 12 14.2 15 18
Environment Humidity 20-90 % RH @ 0- 40°C (non-condensing) 0-95 % RH @ 0- 40C                   (non-condensing)
Noise Level Less than 50dBA @ 1 Meter Less than 55dBA@1Meter Less than 58dBA @1Meter
Management Smart RS232/USB Supports Windows 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC
Optional SNMP Power management from SNMP manager and web browser
*UPS Model with "L" means Long Run UPS Model without bateries
Rack Mountable Online UPS for Servers with 2u 3u 5u

Rack Mountable Online UPS for Servers with 2u 3u 5u

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now