Customization: | Available |
---|---|
Phase: | Three Phase |
Type: | On-line |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
LS33 Series 10K - 200Kva | |||||||||||
MODEL | LS33 10K | LS33 20K | LS33 30K | LS33 40K | LS33 60K | LS33 80K | LS33 100K | LS33 120K | LS33 160K | LS33 200K | |
CAPACITY | 10KVA /8KW | 20KVA /16KW | 30KVA /24KW | 40KVA /32KW | 60KVA /48KW | 80KVA /64KW | 100KVA /80KW | 120KVA /96KW | 160KVA /128KW | 200KVA /160KW | |
INPUT | |||||||||||
Nominal Voltage | 3 x 380VAC/400VAC (3Ph + N) | ||||||||||
Acceptable Voltage Range | 305VAC ~ 460VAC | ||||||||||
Frequency | 46-54Hz or 56-64Hz | ||||||||||
INVERTER | |||||||||||
Nominal Voltage | 3 * 380VAC/400VAC (3Ph + N) | ||||||||||
Precision | Stationary: ±1% Transitory: ±5% (load variations 100-0-100%) |
||||||||||
Frequency | 50/60 Hz synchronised ±1 % With mains absent ±0.1 Hz | ||||||||||
Max. Synchronisation Speed | ±1 Hz/s | ||||||||||
Waveform | Pure Sinewave | ||||||||||
Total Harmonic Distortion (THDv) | <2% (Linear Load) <5% (Non-linear Load) |
||||||||||
Phase Displacement | 120o ±1% (balanced load) 120o ±2% (imbalances 50% of the load) |
||||||||||
Dynamic Recovery Time | 1 cycle at 98 % of the static value | ||||||||||
Admissible Overload | 110% for 10min; 150% for 60sec ; >160% for 200ms | ||||||||||
Admissible Crest Factor | 3:1 | ||||||||||
Admissible Power Factor | 0.6~1 (inductive or capacitive) | ||||||||||
Imbalance Output Voltage @ 100% Unbalanced Load | <1% | ||||||||||
Current Limit | High overload, short-circuit: RMS Voltage Limit High Crest-Factor current: Peak Voltage Limit |
||||||||||
STATIC BYPASS | |||||||||||
Type | Solid state | ||||||||||
Voltage | 3 x 380VAC/400VAC (3Ph + N) | ||||||||||
Frequency | 50/60 Hz | ||||||||||
Activation Criterion | Microprocessor control | ||||||||||
Transfer Time | Zero | ||||||||||
Admissible Overload | 150% for 1 hour; 180% for 30sec; >200% for 200ms | ||||||||||
Transfer to Bypass | Immediate, for overloads above 160% | ||||||||||
Retransfer | Automatic after alarm clear | ||||||||||
MAINTENANCE BYPASS | |||||||||||
Type | Without interruption | ||||||||||
Voltage | 3 * 400V (3Ph + N) | ||||||||||
Frequency | 50/60 Hz | ||||||||||
Overall Efficiency | Line Mode | 90% | 91% | 92% | 93% | ||||||
Battery Mode | 90% | 91% | 93% | 93% | |||||||
BATTERY & CHARGER | |||||||||||
Battery Type and Numbers | 12VDC* 16 pcs | 12VDC * 32 pcs (29~32 pcs adjustable) | |||||||||
Nominal Battery Voltage | 192 VDC | 384 VDC (Based on 32pcs batteries) | |||||||||
Charging Method | CC/CV | ||||||||||
Precision | ±1% | ||||||||||
Charging Current | Max.: 40 A | ||||||||||
Charging Voltage | 216 VDC | 432 VDC (Based on 32pcs batteries) | |||||||||
PHYSICAL | |||||||||||
Dimensions, D*W*H(mm) | 656*405* 817 | 656*405* 941 | 840*432*1140 | 975 *554 *1286 | 1200 *910 *1680 | 1500 *1140 *1800 | |||||
Net Weight (Kgs) | 180 | 205 | 295 | 330 | 451 | 519 | 950 | 1350 | |||
* Product specifications are subject to change without further notice |