Phase: | Single Phase |
---|---|
Type: | On-line |
Protection: | Overvoltage |
Application: | Fire Safety |
Classification: | Lighting/Power |
Standby Time: | Long-acting Machine |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
green star 6k/10k online ups specification | |||
model | g6k (l) | g10k (l) | |
phase | 1 phase in / 1 phase out | ||
capacity | 6000 va / 4800 w | 10000 va / 8000 w | |
input | |||
nominal voltage | 208/220/230/240vac | ||
voltage range | low line loss | 110 vac ± 3% at 50% load 176 vac ± 3% at 100% load |
|
low line comeback | 120 vac ± 3% at 50% load 186 vac ± 3% at 100% load |
||
high line loss | 300 vac ± 3% | ||
high line comeback | 290 vac ± 3% | ||
frequency range | 46 hz ~ 54 hz or 56 hz ~ 64 hz | ||
power factor | >= 0.99 @ 100% load | ||
output | |||
nominal voltage | 208/220/230/240vac | ||
ac voltage regulation | ± 1% | ||
frequency range (synchronized range) | 46 hz ~ 54 hz or 56 hz ~ 64 hz | ||
frequency range (batt. mode) | 50 hz ± 0.1 hz or 60 hz ± 0.1 hz | ||
current crest ratio | 3:1 (max.) | ||
harmonic distortion | <= 3 % thd (linear load) <= 6 % thd (non-linear load) |
||
transfer time | bypass to inverter (line mode) | zero | |
inverter to bypass (line mode) | zero | ||
waveform (batt. mode) | pure sinewave | ||
efficiency | |||
line mode | 89% | 90% | |
battery mode | 88% | 89% | |
battery | |||
standard model | battery type | 12 v / 7 ah | 12 v / 9 ah |
numbers | 16 | 16 | |
typical recharge time | 9 hours recover to 90% capacity | ||
charging current | default:1.0 a ± 10%, max.:2.0a ± 10% | default:1.0 a ± 10%, max.:2.0a ± 10% | |
float charging voltage | 218.4 vdc ± 1% | ||
long-run model | battery type | depending on applications | |
numbers | 16-20** (adjustable) | ||
charging current | default:4.0 a ± 10%, max.:6.0a ± 10% | default:4.0 a ± 10%, max.:6.0a ± 10% | |
float charging voltage | 273 vdc ± 1% (based on 20 pcs batteries) | ||
indicators | |||
lcd panel | ups status, load level, battery level, input/output voltage, discharge timer, and fault conditions | ||
alarm | |||
battery mode | sounding every 4 seconds | ||
overload | sounding twice every second | ||
fault | continuously sounding | ||
physical | |||
standard model | dimension, d x w x h (mm) | 369 x 190 x 688 | 442 x 190 x 688 |
net weight (kgs) | 60 | 75 | |
long-run model | dimension, d x w x h (mm) | 369 x 190 x 318 | 442 x 190 x 318 |
net weight (kgs) | 21 | 23 | |
environment | |||
operation humidity | 0-95 % rh @ 0- 40°c (non-condensing) | ||
noise level | less than 55dba @ 1 meter | less than 58dba @ 1 meter | |
management | |||
smart rs-232/usb | supports windows® 2000/2003/xp/vista/2008, windows® 7/8, linux, unix, and mac | ||
optional snmp | power management from snmp manager and web browser | ||
*derate capacity to 60% of capacity in cvcf mode and to 90% when the output voltage is adjusted to 208vac. | |||
*if the ups is installed or used in a place where the altitude is above than 1000m, the output power must be derated | |||
one percent per 100m. | |||
*product specifications are subject to change without further notice |