Single phase Tower and Rack Convertible rack mount online UPS
High Frequency Online UPS Rack Tower Star Series RT 1K-10KVA(1Ph in/1Ph out)
Key Features:
1:Full digital control (DSP)
2:Rack Mount - Tower Convertible
3:Self-detection when UPS start-up
4:Rack and tower in universal body
5:Diverse options of accessories, intelligent management
6:Comprehensive protection for the total unit
7:friendly and intuitive interface, full protection for the equipment
8:It has voltage breakthrough protection and strong anti-interference function.
9:It provides the best power source guarantee for the load equipments for users.
10:Sine wave output no matters in AC mode or battery mode can provide sine wave power source with low distortion.
11:Zero delay: when the utility power is cut off or recover, there is absolutely no time between the transfer of AC mode and battery mode. It effectively ensures the reliability of load operation.
12:Active Input Power Factor Correction (PFC), UPS can correct the input power factor. Under full load, the input power factor can reach over 0.95 so that the electric environment of the users will not be polluted.
Applications
Servers, Military,Medical Systems,Network sensitive electronic equipment,Astronautics,Electronic & Telecom
,Army Technology,Securities System,Sensitive Electronic Equipment,Wind Power System,Production Equipment,Military,Medical Systems,Network,Instrumentation etc.
Technical Specification
MODEL(RT Series) |
RT1K |
RT1KL |
RT2K |
RT2KL |
RT3K |
RT3KL |
RT6KL |
RT10KL |
Input |
Rated Capacity |
1KVA/800W |
2KVA/1600W |
3KVA/2400W |
6KVA/4800W |
10KVA/8000W |
Voltage |
90 ± 5 ~290 ± 5Vac |
176 ~ 276Vac |
Current |
6A(max) |
12A(max) |
16A(max) |
31A(max) |
60A(max) |
Frequency |
40 ~ 60 Hz |
Power factor |
Conformity EN60555-2(≥0.95) |
≥0.95(MAX) |
Output |
Voltage |
220Vac ( 1 ± 2%) |
220Vac ( 1 ± 1%) |
Current |
4.55A |
9.1A |
13.6A |
27.3A |
54A |
Frequency |
(50 ± 2)Hz |
(50 ± 1)Hz |
Power Factor |
0.8 lag |
Waveform |
Sine Wave |
Waveform |
Linear ≤ 7% when RCD 100% loading (Non-line) |
Distortion |
Linear ≤ 3% when RCD 100% loading (line) |
Overload protection |
105%< <125% → 50s |
100%-125%, 1 minutes to |
125%< <150% → 25s |
transfer to bypass; >150%, |
>150% → 300s |
100ms to transfer to bypass |
Transfer Time |
Oms |
Type of Battery |
Sealed lead acid maintenance-free |
External Battery Voltage |
3x7 Ah |
36Vdc |
6x7 Ah |
72Vdc |
8x7 Ah |
96Vdc |
192Vdc/240Vdc |
Working |
Operating |
0-40ºC |
Environment |
Temperatures(ºC) |
|
Relative |
0-90(%) |
|
Temperature(ºC) |
|
Altitude |
<1500m |
Communication |
9pin D trpe comector (RS232) |
Size (WXDXH) mm |
482x450x88 |
Standard Type (3U): 482x680x132.5 |
482x680x132.5 |
Long Backup Type (2U): 482x450x88 |
Weight (kg) |
14.5 |
8 |
22 |
9.8 |
26 |
9.8 |
20 |
25 |