Customization: | Available |
---|---|
Phase: | Three Phase |
Type: | On-line |
Still deciding? Get samples of US$ 500/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
380/400/415Vac three phase Online Uninterruptible Power Supply for Control Equipment
High Frequency Online UPS Queen Star Plus Strar Series 33Q10K-80K(3Ph in/3Ph out)
Applications
Data center, Industrial equipment, Financial and Securities, Large Data rooms,Postal and Telecommunications,Micro Processor Based Office Machines, Energy and Electricity, Industrial and Commercial tax affair,Control Equipment,railway stations, airports and seaports etc.
Technical Specification: | |||||||
Index | 33Q 10KL | 33Q 20KL | 33Q 30KL | 33Q 40KL | 33Q 60KL | 33Q 80KL | Comments |
Input | |||||||
Input voltage | |||||||
Rated voltage | 380VAC/220VAC | 380VAC | |||||
Phase | three phase with ground | ||||||
Turn on voltage range |
(120±5~274±5)VAC | (207±9~475±9) VAC |
|||||
Bypass voltage range |
(60±5~300±5)VAC | (105±9~518±9) VAC |
Could be adjusted by software. |
||||
Bypass low loss |
60VAC~220VAC(default 60VAC) | 105VAC~380VAC (default 105VAC) |
|||||
Bypass low comeback |
Low loss +5VAC | Low loss +17VAC |
|||||
Bypass high loss |
220VAC~300VAC(default 300VAC) | 380VAC~475VAC (default 475VAC) |
|||||
Bypass high comeback |
High loss -5VAC | High loss -17VAC | |||||
Line low loss comeback |
(120±5) VAC /(140±5) VAC | (207±9) VAC (242±9) VAC |
load≤50% | ||||
(140±5) VAC /(160±5) VAC | (242±9) VAC (276±9) VAC |
50%≤90% | |||||
(160±5) VAC /(175±5) VAC | (276±9) VAC (302±9) VAC |
load>90% | |||||
Line high loss comeback |
(275±5)VAC/(260±5)VAC | (475±9)VAC (449±9)VAC |
|||||
Input frequency | |||||||
Rated frequency |
50Hz | ||||||
Frequency low loss |
(40~49) ±0.2Hz(default:46Hz) | Could be adjusted by software. |
|||||
Frequency low comeback |
Frequency low loss +0.5Hz | ||||||
Frequency high loss |
(51~60)±0.2Hz(default:54Hz) | ||||||
Frequency high comeback |
Frequency high loss -0.5Hz | ||||||
Input power factor | |||||||
Could be adjusted by software. |
> 0.99 | 33Q 10-40KL: 220VAC,full R load 33Q 60-80KL: 380VAC,full R load |
|||||
Generator | Support generator input | Generator rating ≥2*UPS rating |
|||||
Input current | |||||||
Rated current | 14A | 28A | 42A | 67A | 80A | 105A | |
Input THDI | <= 10% | ||||||
Output protection | |||||||
Rating protection |
32A Breaker |
50A Breaker |
60A Breaker |
80A Breaker |
100A Breaker |
125A Breaker |
|
Output power | |||||||
VA/watt | 10KVA/8KW | 20KVA/16KW | 30KVA/24KW | 40KVA/32KW | 60KVA/ 48KW |
80KVA/ 64KW |
|
Rated voltage | 220VAC | 380VAC | Sine wave | ||||
Voltage range | 200/208/220 /230/240VAC |
345/359/380 /397/415 VAC |
33Q 10-40KL: Could be adjusted by software. 10% derating for 208VAC /200VAC. 33Q 60-80KL: Could be adjusted by software. 10% derating for 345VAC /359VAC. |
||||
Voltage regulation | ±1% | ||||||
Voltage distortion | ≤5% | ≤10% | Full RCD load | ||||
≤3% | Full R load | ||||||
DC offset | ≤200mV | ||||||
Transient response | ≤9% | R load 0%~100%~0% |
|||||
≤6% | R load 20% ~100%~20% |
||||||
Transient recovery | ≤60ms voltage recovery to 90% | Full RCD load | |||||
Bypass output before turn-on |
YES | ||||||
Crest ration | 3:1 | ||||||
Output frequency range | |||||||
Normal mode | 1,Same as input frequency(46Hz~54Hz) 2,50Hz(Input frequency>54Hz or Input frequency<46Hz) |
||||||
Battery mode | (50±0.1) Hz | ||||||
Slew rate | 1 Hz/Sec | ||||||
Efficiency | |||||||
Normal mode | > 93% | > 90% | |||||
Battery mode | > 90% | > 90% | |||||
Overload | |||||||
Normal mode battery mode |
Overload warning only | 105%±5%≤load | |||||
1min,then transfer to bypass and alarm. | 105%±5%< load≤125%±5% |
||||||
30S,then transfer to bypass and alarm. | 125%±5%< load≤150%±5% |
||||||
300mS, then transfer to bypass and alarm. | load>150%±5% | ||||||
Automatically retransfer |
YES | ||||||
Short protection | |||||||
Normal battery mode |
YES | ||||||
Transfer time | |||||||
Normal to battery mode |
0mS | ||||||
Battery to normal mode |
0mS | ||||||
Normal to bypass mode |
<4mS | 0mS | |||||
Bypass to normal mode |
<4mS | 0mS | |||||
Battery and charger | |||||||
Battery | |||||||
Rated voltage | 192VDC | 240VDC | 192VDC*2 | 192VDC*2 | 480VDC | ||
Type/Rating | |||||||
Battery quantity |
16 | 20 | 16*2 | 16*2 | 40 | ||
Backup time | |||||||
Protection | |||||||
Low alarm voltage comeback voltage |
(180.8V±4V)/ (188.8V±4V) | (226V±4V)/ (236V±4V) | (180.8V±4V) (188.8V±4V) |
(226V±4V)/ (236V±4V) | (452V±4V) (472V±4V) |
33Q 30KL use two |
|
Shutdown voltage comeback voltage |
160V±4V/ 168V±4V |
(200V±4V)/ (210V±4V) | 160V±4V/ 168V±4V |
(200V±4V)/ (210V±4V) | (400V±4V) (420V±4V) |
||
DC protection | |||||||
Overcharge protection comeback voltage |
(249.6V±4V) (216V±4V) |
(312V±4V) (270V±4V) | (249.6V±4V) (216V±4V) |
(312V±4V) (270V±4V) | (624V±4V) (540V±4V) |
||
Leakage current | < 500uA | ||||||
Over discharge protection |
14.5h | Could be set by software |
|||||
Battery test | |||||||
Battery weak | YES | ||||||
Battery fault | YES | ||||||
Charger | |||||||
Output voltage | (219.2±3)VDC | (277±3)VDC | (219.2±3)VDC | (277±3)VDC | (554±3)VDC | ||
Charge time | Depends on the external battery capacity | ||||||
Charge current | 7.5A | 6A | 5A | 4A | 10A | ||
Interface | |||||||
Alarm silence | YES | ||||||
DC power turn-on |
YES | ||||||
Automatically retransfer |
YES | ||||||
Audio alarm | |||||||
Battery mode | Beep/4s | ||||||
Battery low charger fault |
Beep/1s | ||||||
UPS fault | Continue beep | ||||||
Overload | Beep/1s | ||||||
Bypass mode | Beep/2Min | ||||||
L/N inverse | Beep/2Min | ||||||
Communication | |||||||
RS232 interface | YES | ||||||
Intelligent slot | YES | ||||||
Monitor software | Appending with UPS | ||||||
Cooling | |||||||
Force air cooling | |||||||
Display | |||||||
LCD/LED displays UPS status | |||||||
Environment | |||||||
Work temperature |
0ºC~40ºC | ||||||
Altitude | <1000m | ||||||
Audible noise |
≤60dB | ||||||
Storage temperature |
-15ºC~45ºC | ||||||
Work humidity | 20%~95% | ||||||
Standard | |||||||
EMS | |||||||
ESD | IEC61000-4-2 | Level4 | |||||
RS | IEC61000-4-3 | Level3 | |||||
EFT | IEC61000-4-4 | Level4 | |||||
Surge | IEC61000-4-5 | Level4 | |||||
EMI | |||||||
Conducted | EN55022 | Class A | |||||
Radiated | EN55022 | Class A | |||||
Safety | |||||||
Safety | GB4943-2001/IEC62040-1 | ||||||
Machinery features | |||||||
Size | |||||||
Outline dimension and net weight | |||||||
L*W*H (mm) | 710*260*717 | 840*515*1135 | |||||
Net weight(Kg) | 45/93 | 50/98 | 195 | 208 | |||
Optional functions | |||||||
60Hz | Optional | Set by software | |||||
Converter mode | Optional | Set by software | |||||
ECO | Optional | Optional | Available and set by software |
||||
EPO | Optional | Optional | |||||
LCD display | Optional |
Shenzhen UPSEN Electronic CO., Ltd. locates in south of China, Shenzhen City, close to Pearl of the Orient HK, with beautiful environment and convenient transport.
We are a private high-tech enterprise integrating researching & development, production & operation and technical services as a whole, which is specialized in Electric, Electronic and Energy fields for a long time. Our main products are UPS Power, Inverter Power, Battery Power, Solar&Wind Power. We are dedicated to offer quality power and power solution for Data-center,Telecom, Bank, Hospital, Transportation, Industry, A-rmy, Security, and civil & office area etc. Moreover, we have mastered the core technology of power products through our independent research, we are one of few domestic enterprises which can meet the customers' customized requirements, and provide professional power solutions.
We already past ISO9001 international quality system certification, and established a complete quality system ranging from material source, process, assembling to testing. All our products are with CE Certificate, which exported to more than 30 countries and areas, like Australia, Europe, Africa, North America, South America, the Middle East, central Asia, southeast Asia etc.
We will always offer excellent quality and products to customers. Hope to make Integrity and Double-Win business with you, and to be your professional power supplier and solve your any power problems.We are sure UPSEN can achieve more successes with our efforts and your support.
1: High working efficiency and production, to be sure compeitive price
2: Strict material quality control, to be sure all materials meet CE standards
3: Independent test equipment suitable for most international standard tests
4:Each process been tested before assembling which can assure low fault rate, and improve shortages
5: Professional R&D Engineers with average bachelor degree
6: Products average upgrading every 1.5~2 years
7: 1% free unit or 2% free parts for timely warranty service
8: Free technical support before and after sales
Q1. What is packing?
A: Generally, we pack our goods in neutral white boxes and brown cartons. If you have legally registered patent,
We can pack the goods in your branded boxes after getting your authorization letters.
Q2. What is your terms of payment?
A: T/T 30% as deposit, and 70% before delivery. We'll show you the photos of the products and packages before you pay the balance.
Q3. What is your terms of delivery?
A: EXW, FOB, CFR, CIF, DDU.
Q4. How about your delivery time?
A: Generally, it will take 7-20 days after receiving your advance payment.
The specific delivery time depends on the items and the quantity of your order.
Q5. Can you OEM and ODM Service?
A: Yes, we can provide free OEM Service, and ODM Service is available for volume order too.
Q6. Do you test all your goods before delivery?
A: Yes, all our products have more than 6~8 hours for againg, and strict test before dispatch
Q7. Do you have any MOQ limit?
A: Low MOQ, 5 pieces for sample checking is available.
Q8. Can I have a sample order?
A: Yes, sample order is acceptable to test and check quality for the first cooperation
Q9. How to proceed with an order?
A: Initially, let us know your requirements or application. Besides, We quote according to your requirements or our suggestions. Thirdly, customers confirm the samples and places deposit for formal order. Finally, We arrange production.