Digital Control Double Conversion Online UPS for Internet Servers

Product Details
Customization: Available
Phase: Three Phase
Type: On-line
Still deciding? Get samples of US$ 100/Piece
Request Sample
Diamond Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Plant Area
>2000 square meters
Management System Certification
ISO 9001, ISO 14001
  • Digital Control Double Conversion Online UPS for Internet Servers
  • Digital Control Double Conversion Online UPS for Internet Servers
  • Digital Control Double Conversion Online UPS for Internet Servers
Find Similar Products

Basic Info.

Model NO.
Queen Star Plus 33Q10K-80K
Application
Fire Safety
Classification
Lighting/Power
Standby Time
Standard Machine
Standby UPS
Sine Wave Output UPS
Output Capacity
Large Type
Equipment Mode
Decentralized
Brand
Upsen
Transfer Time
0ms
Efficiency
95-99%
Output Voltage
380/400/415
Battery Type
Lead Acid Battery
Transport Package
Cartons & Wooden Pallet
Specification
CE & ISO Certificate
Trademark
UPSEN
Origin
China
HS Code
8504402000
Production Capacity
50, 000PCS/Month

Product Description

Digital Control  Double Conversion Online UPS for Internet Servers
High Frequency Online UPS Queen Star Plus Strar Series 33Q10K-80K(3Ph in/3Ph out)
 
Key Features:
1:UPS with Advanced parallel technology.
2:UPS with Intelligent battery management (ABM).
3:Fully digital control with three DSPs including IGBT rectifier, inverter, charger.
4:UPS can be easily interconnected owning to the special control technology.
5:Support battery cold start and mains supply self-stating, satisfy the user's requirement.
6:Touch screen display, with the simple operation and Intuitive data, optional display language and logo
7:Itelligent self-diagnose function, all kinds of fault protection, large capability of history recored storge.
8:Complete isolation design between fragile components and air flue, improving the system reliability greatly.

UPS Application
Internet Servers ,Internet Data Center, Medium-scale network system ,Data processing systems, bank and securities, Emergency lighting systems, Medium-scale office automation, precision equipment,etc. 
 
Technical Specification
Technical Specification:
Index 33Q 10KL 33Q 20KL 33Q 30KL 33Q 40KL  33Q 60KL  33Q 80KL Comments
Input
Input voltage
Rated voltage 380VAC/220VAC 380VAC  
Phase three phase with ground  
Turn on 
voltage range
(120±5~274±5)VAC (207±9~475±9)
VAC
 
Bypass 
voltage range
(60±5~300±5)VAC (105±9~518±9)
VAC
Could be 
adjusted 
by software.
Bypass 
low loss
60VAC~220VAC(default 60VAC) 105VAC~380VAC
(default 105VAC)
 
Bypass
 low comeback
Low loss +5VAC Low loss 
+17VAC
 
Bypass 
high loss
220VAC~300VAC(default 300VAC) 380VAC~475VAC
(default 475VAC)
 
Bypass 
high comeback
High loss -5VAC High loss -17VAC  
Line low loss
comeback
(120±5) VAC /(140±5) VAC (207±9) VAC 
(242±9) VAC
load≤50%
(140±5) VAC /(160±5) VAC (242±9) VAC
(276±9) VAC
50%≤90%
(160±5) VAC /(175±5) VAC (276±9) VAC
(302±9) VAC
load>90%
Line high loss
comeback
(275±5)VAC/(260±5)VAC (475±9)VAC
(449±9)VAC
 
Input frequency
Rated 
frequency
50Hz  
Frequency 
low loss
(40~49) ±0.2Hz(default:46Hz) Could be 
adjusted
 by software.
Frequency 
low comeback
Frequency low loss +0.5Hz
Frequency 
high loss
(51~60)±0.2Hz(default:54Hz)
Frequency 
high comeback
Frequency high loss -0.5Hz
Input power factor
Could be 
adjusted 
by software.
> 0.99 33Q 10-40KL:
220VAC,full R load
33Q 60-80KL: 
380VAC,full R load
Generator  Support generator input Generator rating
≥2*UPS rating
Input current
Rated current  14A 28A 42A 67A 80A 105A  
Input THDI <= 10%  
Output protection
Rating 
protection
32A 
Breaker
50A 
Breaker
60A 
Breaker
80A 
Breaker
100A 
Breaker
125A 
Breaker
 
Output power
VA/watt 10KVA/8KW 20KVA/16KW 30KVA/24KW 40KVA/32KW 60KVA/
48KW
80KVA/
64KW
 
Rated voltage 220VAC 380VAC Sine wave
Voltage range 200/208/220
/230/240VAC
345/359/380
/397/415 VAC
33Q 10-40KL: 
Could be 
adjusted 
by software. 
10% derating 
for 
208VAC
/200VAC.
33Q 60-80KL: 
Could be 
adjusted 
by software. 
10% derating 
for 345VAC
/359VAC.
Voltage regulation ±1%  
Voltage distortion ≤5% ≤10% Full RCD load
≤3% Full R load
DC offset ≤200mV  
Transient response ≤9% R load 
0%~100%~0%
  ≤6% R load 20%
~100%~20%
Transient recovery ≤60ms voltage recovery to 90% Full RCD load
Bypass output 
before turn-on
YES  
Crest ration 3:1  
Output frequency range
Normal mode 1,Same as input frequency(46Hz~54Hz)
2,50Hz(Input frequency>54Hz or Input frequency<46Hz)
 
Battery mode (50±0.1) Hz  
Slew rate 1 Hz/Sec  
Efficiency
Normal  mode > 93% > 90%  
Battery mode > 90% > 90%  
Overload
Normal mode
battery mode 
Overload warning only 105%±5%≤load
1min,then transfer to bypass and alarm. 105%±5%<
load≤125%±5%
30S,then transfer to bypass and alarm. 125%±5%<
load≤150%±5%
300mS, then transfer to bypass and alarm. load>150%±5%
Automatically
 retransfer
YES  
Short protection
Normal
battery mode
YES  
Transfer time
Normal to 
battery mode
0mS  
Battery to 
normal mode
0mS  
Normal to 
bypass mode
<4mS 0mS  
Bypass to 
normal mode
<4mS 0mS  
Battery and charger
Battery
Rated voltage 192VDC 240VDC 192VDC*2 192VDC*2 480VDC  
Type/Rating            
Battery 
quantity
16 20 16*2 16*2 40  
Backup time            
Protection
Low alarm voltage 
comeback voltage
(180.8V±4V)/ (188.8V±4V) (226V±4V)/ (236V±4V) (180.8V±4V)
(188.8V±4V)
(226V±4V)/ (236V±4V) (452V±4V)
(472V±4V)
33Q 30KL 
use two 
Shutdown voltage
comeback voltage
160V±4V/
168V±4V
(200V±4V)/ (210V±4V) 160V±4V/
168V±4V
(200V±4V)/ (210V±4V) (400V±4V)
(420V±4V)
 
DC protection
Overcharge 
protection
comeback voltage
(249.6V±4V)
(216V±4V)
(312V±4V) (270V±4V) (249.6V±4V)
(216V±4V)
(312V±4V) (270V±4V) (624V±4V) 
(540V±4V)
 
Leakage current < 500uA  
Over 
discharge
 protection
14.5h   Could be 
set by software
Battery test
Battery weak YES  
Battery fault YES  
Charger
Output voltage (219.2±3)VDC (277±3)VDC (219.2±3)VDC (277±3)VDC (554±3)VDC  
Charge time Depends on the external battery capacity  
Charge current 7.5A 6A 5A 4A 10A  
Interface
Alarm silence YES  
DC power 
turn-on
YES  
Automatically
 retransfer
YES  
Audio alarm
Battery mode Beep/4s  
Battery low
charger fault
Beep/1s  
UPS fault Continue beep  
Overload Beep/1s  
Bypass mode Beep/2Min  
L/N inverse Beep/2Min  
Communication
RS232 interface YES  
Intelligent slot YES  
Monitor software Appending with UPS  
Cooling
Force air cooling  
Display
LCD/LED displays UPS status
Environment
Work 
temperature
0ºC~40ºC  
Altitude <1000m  
Audible
 noise
≤60dB  
Storage 
temperature
-15ºC~45ºC  
Work humidity 20%~95%  
Standard
EMS
ESD IEC61000-4-2 Level4
RS IEC61000-4-3 Level3
EFT IEC61000-4-4 Level4
Surge IEC61000-4-5 Level4
EMI
Conducted EN55022 Class A
Radiated EN55022 Class A
Safety
Safety GB4943-2001/IEC62040-1  
Machinery features
Size
Outline dimension and net weight
L*W*H (mm) 710*260*717 840*515*1135  
Net weight(Kg) 45/93 50/98     195 208  
Optional functions
60Hz     Optional Set by software
Converter mode     Optional Set by software
ECO Optional Optional Available and 
set by software
EPO Optional Optional  
LCD display Optional    

Digital Control Double Conversion Online UPS for Internet Servers


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier