High Frequency Online UPS Queen Star Plus Series 6K-10Kva
Product Advantages:
Key Features:
Application:
Network, data centre, servers and workstations, control system, communication system, Telecom system, power station,security system, hospital, school, Air Conditioner, Laser Printer, home and office etc.
Technical Specification
Queen Star Plus Series 6K - 10K | |||||
Index | Q6K Plus | Q6KL Plus | Q10K Plus | Q10KL Plus | Comments |
Input | |||||
Input voltage | |||||
Rated voltage | 220VAC | ||||
Phase | Single phase with ground | ||||
Turn on voltage range | (120±5~274±5)VAC | ||||
Bypass voltage range | (60±5~300±5)VAC | Could be adjusted by software. | |||
Bypass low loss | 60VAC~220VAC(default 60VAC) | ||||
Bypass low comeback | Low loss +5VAC | ||||
Bypass high loss | 220VAC~300VAC(default 300VAC) | ||||
Bypass high comeback | High loss -5VAC | ||||
Line low loss/comeback | (120±5) VAC /(140±5) VAC | load≤50% | |||
(150±5) VAC /(165±5) VAC | 50%<load≤80% | ||||
(160±5) VAC /(175±5) VAC | 80%<load | ||||
Line high loss/comeback | (274±5)VAC/(260±5)VAC | ||||
Input frequency | |||||
Rated frequency | 50Hz | ||||
Frequency low loss | (40~49) ±0.2Hz(default:46Hz) | Could be adjusted by software. | |||
Frequency low comeback | Frequency low loss +0.5Hz | ||||
Frequency high loss | (51~60)±0.2Hz(default:54Hz) | ||||
Frequency high comeback | Frequency high loss -0.5Hz | ||||
Input power factor | |||||
Input power factor | > 0.99 | Q6K Plus & Q6KL Plus: 220VAC, full R load Q10K Plus & Q10KL Plus: full R load |
|||
Generator | Support generator input | Generator rating ≥2*UPS rating | |||
Input current | |||||
Rated current | 25A | 27A | 41A | 43A | |
Input THDI | 10% | ||||
Output protection | |||||
Rating protection | 32A Breaker | 50A Breaker | |||
Output power | |||||
VA / watt | 6000/4800 | 10000/8000 | |||
Rated voltage | 220VAC | Sine wave | |||
Voltage range | 200/208/220/230/240VAC | Q6K Plus & Q6KL Plus: Could be adjusted by software. 10% derating for 208VAC/200VAC. | |||
Voltage regulation | ±1% | ||||
Voltage distortion | ≤6% | Full RCD load | |||
≤2% | Full R load | ||||
DC offset | ≤200mV | ||||
Transient response | ≤9% | R load 0%~100%~0% | |||
≤6% | R load 20%~100%~20% | ||||
Transient recovery | ≤60ms voltage recovery to 90% | Full RCD load | |||
Bypass output before turn-on |
YES | ||||
Crest ration | 3:1 | ||||
Output frequency range | |||||
Normal mode | 1,Same as input frequency(46Hz~54Hz) 2,50Hz(Input frequency>54Hz or Input frequency<46Hz) |
||||
Battery mode | (50+0.1) Hz | ||||
Slew rate | 1 Hz/Sec | ||||
Efficiency | |||||
Normal mode | > 93% | ||||
Battery mode | > 91% | ||||
Overload | |||||
Normal mode/battery mode | Overload warning only | 105%±5%≤load | |||
1min,then transfer to bypass and alarm. | 105%±5% | ||||
30S,then transfer to bypass and alarm. | 125%±5% | ||||
100mS, then transfer to bypass and alarm. | load>135%±5% | ||||
Automatically retransfer | YES | ||||
Short protection | |||||
Normal / battery mode | YES | ||||
Transfer time | |||||
Normal to battery mode | 0mS | 0mS | |||
Battery to normal mode | 0mS | 0mS | |||
Normal to bypass mode | <4mS | 0mS | Q6K Plus & Q6KL Plus: 0mS (option)with load |
||
Bypass to normal mode | <4mS | 0mS | |||
Battery and charger | |||||
Battery | |||||
Rated voltage | 192VDC | ||||
Type / Rating | Sunshin7AH/12V | Sunshine 9AH/12V | |||
Battery quantity | 16 PCS | 16 PCS | |||
Backup time | > 14min | >8min | Half load | ||
Protection | |||||
Low alarm voltage/ comeback voltage |
(180.8V±4V)/ (188.8V±4V) | ||||
Shutdown voltage/ comeback voltage |
(176V±4V)/ (184V±4V) | (176V±4V)/ (184V±4V) | (176V±4V)/ (184±4V) | (176V±4V)/ (184±4V) | Load < 1000W |
(152V±4V)/ (160V±4V) | (160V±4V)/ (168V±4V) | (152V±4V)/ (160±4V) | (160V±4V)/ (168±4V) | Load>= 1000W | |
DC protection | |||||
Overcharge protection/ comeback voltage |
(249.6V±4V) / (216V±4V) | ||||
Leakage current | < 500uA | ||||
Over discharge protection | 14.5h | Could be set by software | |||
Battery test | |||||
Battery weak | YES | ||||
Battery fault | YES | ||||
Charger | |||||
Output voltage | (219.2±3)VDC | ||||
Charge time | 7 hours to 90% capacity | ||||
Charge current | 1A | 5.5A | 1A | 5.5A | |
Interface | |||||
Alarm silence | YES | ||||
DC power turn-on | YES | ||||
Automatically retransfer | YES | ||||
Audio alarm | |||||
Battery mode | Beep/4s | ||||
Battery low / charger fault | Beep/1s | ||||
UPS fault | Continue beep | ||||
Overload | Beep/1s | ||||
Bypass mode | Beep/2Min | ||||
L / N inverse | Beep/2Min | ||||
Communication | |||||
RS232 interface | YES | ||||
Intelligent slot | YES | ||||
Monitor software | Appending with UPS | ||||
Cooling | |||||
Force air cooling | |||||
Display | |||||
LCD/LED displays UPS status |
|||||
Environment | |||||
Work temperature | 0ºC~40ºC | ||||
Altitude | <1000m | ||||
Audible noise | ≤55dB | ≤60dB | |||
Storage temperature | -15ºC~45ºC | ||||
Work humidity | 20%~95% | ||||
Standard | |||||
EMS | |||||
ESD | IEC61000-4-2 | Level4 | |||
RS | IEC61000-4-3 | Level3 | |||
EFT | IEC61000-4-4 | Level4 | |||
Surge | IEC61000-4-5 | Level4 | |||
EMI | |||||
Conducted | EN55022 | Class B | |||
Radiated | EN55022 | Class B | |||
Safety | |||||
Safety | GB4943-2001/IEC62040-1 | ||||
Transportation | |||||
Drop test | GB-T4857-18 | ||||
Vibration test | B-WR1-129(GB-T14715-93) | ||||
Machinery features | |||||
Size | |||||
Outline dimension and net weight | |||||
L*W*H(mm) | 533*260*560 | 425*190*328 | 533*260*560 | 533*260*501 | |
Net weight (Kg) | 55kg | 12.2kg | 62kg | 21kg | |
Optional functions | |||||
60Hz | Optional | Set by software | |||
Converter mode | Optional | Set by software | |||
ECO | Optional | Available and set by software | |||
EPO | Optional | ||||
LCD display | Optional | ||||
*Specifications change without further notice |