Product Description
Three Phase UPS with Intelligent Battery Management System
1:high Frequency UPS with Inbuilt Batteries
2:high Frequency UPS System is 3/3 phase
3: UPS with Three Phase 380/400/415Vac
4: high Frequency UPS with high quality for bank
UPS Application
Large-medium computer data center, industrial process and other mission-critical equipment
UPS Key Features
1: DSP control
2: Double CPU control
3: Modularize
4: Battery can be sharing
5: Up to 8 units in parallel
6: Compatible with generator
7: Manual maintenance bypass
8: Advanced battery management
9: N+X parallel redundancy
10: Wide input voltage range
11: High output power factor
12: Strong environmental adaptability
13: Strong shock resistance ability
14: EPO function
15: Full protection against over-discharge, overcharge, over load
High Efficiency Strar Series HE33 10K-200K |
Model |
HE33 Series UPS |
Capacity (VA) |
10K |
15K |
20K |
30K |
40K |
60K |
80K |
100K |
120K |
160K |
200K |
Noninal output capacity |
8KW |
12KW |
16KW |
24KW |
32KW |
48KW |
64KW |
80KW |
96KW |
128KW |
160KW |
Operate type |
Double conversion online type |
Input |
Nominal voltage |
220V/380, 230/400, 240/415V |
Voltage Tolerance |
380/400/415V±25% |
Frequency |
50Hz/60Hz±5% |
Permitted Frequency Tolerance |
±2% (selectable from ±1% to 5% from the front panel) |
Soft start |
0-100% in 30" (selectable) |
Input power factor |
0.95(with input filter) |
Standard features |
Back Feed protection separable bypass line |
|
Phase |
Three phase +N+G |
Output |
Voltage |
220V/380, 230/400, 240/415V, ±1% (stable load), ±5%(active load) |
Frequency |
50/60Hz (±5%, AC mode), 50/60Hz (±1%, Battery mode) |
Static stability |
±5% in 19ms |
Distortion |
Linear load <3%, non linear load<5% |
Power factor |
0.8 |
Output wave |
Pure sine wave |
Crest factor |
3:01 |
Battery voltage |
Standard battery voltage |
384V |
432V |
480V |
Floating charge |
432V |
486V |
540 |
Terminal voltage |
336V |
378V |
420V |
Charge current |
1A-50A (Can calculate and set according to battery configuration software) |
Maximum Discharge Current |
28 |
42 |
56 |
85 |
113 |
169 |
225 |
282 |
338 |
381 |
507 |
Main Function |
Active voltage change |
0-100%±5% |
Instant recover time |
<10ms |
Imbalance voltage |
<±5%,<±1%( Balance load voltage) |
Overload capacity |
125% → 10min,150% → 1min |
Static switch |
Automatic |
Protection |
UPS over current, short circuit, battery low voltage, over heat |
Cold method |
Compel aeration ( temperature control mode) |
Noise |
60-65dB |
Display |
LED \ LCD display |
Remote signalling |
Voltage-free contacts |
Remote commands |
EPO and bypass |
Communication Port (Optional) |
double RS232 + remote contacts + 2 communication interface slots |
Alarm |
Alarm with buzzer and indicators |
Environment |
Temperature: 0-40C Humidity: 0-90% |
*Specification are subject to change without prior notice |