• Cold Start Function 1pH in/1pH out High Frequency Online UPS 6K - 10kVA
  • Cold Start Function 1pH in/1pH out High Frequency Online UPS 6K - 10kVA
  • Cold Start Function 1pH in/1pH out High Frequency Online UPS 6K - 10kVA

Cold Start Function 1pH in/1pH out High Frequency Online UPS 6K - 10kVA

Phase: Single Phase
Type: On-line
Protection: Unbalanced Loads
Application: Communication
Classification: Lighting/Power
Standby Time: Standard Machine
Customization:
Diamond Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
Queen Star Plus Series 6K - 10KVA
Standby UPS
Sine Wave Output UPS
Output Capacity
Medium Type
Equipment Mode
Centralized Model
Brand
Upsen
Transport Package
Cartons
Specification
533*260*560mm
Trademark
upsen
Origin
Shenzheng, China
HS Code
8504402000
Production Capacity
50000PCS/Month

Product Description

High Frequency Online UPS Queen Star Plus Series 6K-10Kva

Product Advantages:
  • Latest Tri-level inverter control tech, makes UPS whole efficiency ≥94%, and improve UPS load capacity to support Air Conditioner, Laser Printer etc sensitive loads.
  • Latest soft switch tech in the boost PFC, enable to reduce the PFC IGBT's Voltage spike and switch loss, and improve the UPS capability to resist lighting and Instantaneous over-voltage.
  • Frequency multiplication controlled PFC circuit to reduce the volume of magnetic components, and makes UPS more smart and efficient.
  • PFC and INV adopts hardware current limit design, effectively accelerate the response time of current limit and improve the reliability of UPS.
  • More optimized structure layout, makes the UPS size smaller.
  • More cost-save price
Key Features:
  • Latest Tri-level inverter control tech, whole UPS high efficiency ≥94%.
  • Support sensitive loads like Air Conditioner, Laser Printer etc.
  • True online double conversion technology, Pure Sine Wave Output.
  • 0.8 Output Power Factor, Digital LCD Screen, Zero transfer time.
  • DSP Technology,  compact design, cost-save price
  • Active input power factor correction (PFC).
  • Protection against all types of power problems.
  • Wide range of input voltage and frequency.
  • Active Load Management, cold start function.
  • Sufficient Expansion Slots for USB,AS400,CMC monitoring,SNMP,RS485 and EMD environmen monitoring .
  • Equipped with maintenance bypass switch.
  • Generator Supportable.
  • Sealed lead acid, maintenance free battery
Application:
Network, data centre, servers and workstations, control system, communication system, Telecom system, power station,security system, hospital, school, Air Conditioner, Laser Printer, home and office etc.
Technical Specification
Queen Star Plus Series 6K - 10K
Index Q6K Plus Q6KL Plus Q10K Plus Q10KL Plus Comments
Input
Input voltage
Rated voltage 220VAC  
Phase Single phase with ground  
Turn on voltage range (120±5~274±5)VAC  
Bypassvoltage range (60±5~300±5)VAC Could be adjusted by software.
Bypass lowloss 60VAC~220VAC(default 60VAC)
Bypass low comeback Low loss +5VAC
Bypass high loss 220VAC~300VAC(default 300VAC)
Bypass high comeback High loss -5VAC
Line low loss/comeback (120±5) VAC /(140±5) VAC load≤50%
(150±5) VAC /(165±5) VAC 50%<load≤80%
(160±5) VAC /(175±5) VAC 80%<load
Line high loss/comeback (274±5)VAC/(260±5)VAC  
Input frequency
Rated frequency 50Hz  
Frequency low loss (40~49) ±0.2Hz(default:46Hz) Could be adjusted by software.
Frequency low comeback Frequency low loss +0.5Hz
Frequency high loss (51~60)±0.2Hz(default:54Hz)
Frequency high comeback Frequency high loss -0.5Hz
Input power factor
Input power factor > 0.99 Q6K Plus & Q6KL Plus:
220VAC, full R load
Q10K Plus & Q10KL Plus:
full R load
Generator Support generator input Generator rating≥2*UPS rating
Input current
Rated current 25A 27A 41A 43A  
Input THDI 10%  
Output protection
Rating protection 32A Breaker 50A Breaker  
Output power
VA / watt 6000/4800 10000/8000  
Rated voltage 220VAC Sine wave
Voltage range 200/208/220/230/240VAC Q6K Plus & Q6KL Plus: Could be adjusted by software. 10% derating for 208VAC/200VAC.
Voltage regulation ±1%  
Voltage distortion ≤6% Full RCD load
≤2% Full R load
DC offset ≤200mV  
Transient response ≤9% R load 0%~100%~0%
≤6% R load 20%~100%~20%
Transient recovery ≤60ms voltage recovery to 90% Full RCD load
Bypass output
before turn-on
YES  
Crest ration 3:1  
Output frequency range
Normal mode 1,Same as input frequency(46Hz~54Hz)
2,50Hz(Input frequency>54Hz or Input frequency<46Hz)
 
Battery mode (50+0.1) Hz  
Slew rate 1 Hz/Sec  
Efficiency
Normal  mode > 93%  
Battery mode > 91%  
Overload
Normal mode/battery mode Overload warning only 105%±5%≤load
1min,then transfer to bypass and alarm. 105%±5%
30S,then transfer to bypass and alarm. 125%±5%
100mS, then transfer to bypass and alarm. load>135%±5%
Automatically retransfer YES  
Short protection
Normal/battery mode YES  
Transfer time
Normal to battery mode 0mS 0mS  
Battery to normal mode 0mS 0mS  
Normal to bypass mode <4mS 0mS Q6K Plus & Q6KL Plus:
0mS (option)with load
Bypass to normal mode <4mS 0mS
Battery and charger
Battery
Rated voltage 192VDC  
Type / Rating Sunshin7AH/12V   Sunshine 9AH/12V    
Battery quantity 16 PCS   16 PCS    
Backup time > 14min   >8min   Half load
Protection
Low alarm voltage/
comeback voltage
(180.8V±4V)/ (188.8V±4V)  
Shutdown voltage/
comeback voltage
(176V±4V)/ (184V±4V) (176V±4V)/ (184V±4V) (176V±4V)/ (184±4V) (176V±4V)/ (184±4V) Load < 1000W
(152V±4V)/ (160V±4V) (160V±4V)/ (168V±4V) (152V±4V)/ (160±4V) (160V±4V)/ (168±4V) Load>= 1000W
DC protection
Overcharge protection/
comeback voltage
(249.6V±4V) / (216V±4V)  
Leakage current < 500uA  
Over dischargeprotection 14.5h Could be set by software
Battery test
Battery weak YES  
Battery fault YES  
Charger
Output voltage (219.2±3)VDC  
Charge time 7 hours to 90% capacity        
Charge current 1A 5.5A 1A 5.5A  
Interface
Alarm silence YES  
DC power turn-on YES  
Automatically retransfer YES  
Audio alarm
Battery mode Beep/4s  
Battery low / charger fault Beep/1s  
UPS fault Continue beep  
Overload Beep/1s  
Bypass mode Beep/2Min  
L / N inverse Beep/2Min  
Communication
RS232 interface YES  
Intelligent slot YES  
Monitor software Appending with UPS  
Cooling
Force air cooling
Display
LCD/LED displaysUPS status
 
         
Environment
Work temperature 0ºC~40ºC  
Altitude <1000m  
Audible noise ≤55dB ≤60dB  
Storage temperature -15ºC~45ºC  
Work humidity 20%~95%  
Standard
EMS
ESD IEC61000-4-2 Level4
RS IEC61000-4-3 Level3
EFT IEC61000-4-4 Level4
Surge IEC61000-4-5 Level4
EMI
Conducted EN55022 Class B
Radiated EN55022 Class B
Safety
Safety GB4943-2001/IEC62040-1  
Transportation
Drop test GB-T4857-18  
Vibration test B-WR1-129(GB-T14715-93)  
Machinery features
Size
Outline dimension and net weight
L*W*H(mm) 533*260*560 425*190*328 533*260*560 533*260*501  
Net weight(Kg) 55kg 12.2kg 62kg 21kg  
Optional functions
60Hz Optional Set by software
Converter mode Optional Set by software
ECO Optional Available and set by software
EPO Optional  
LCD display Optional  
*Specifications change without further notice
Cold Start Function 1pH in/1pH out High Frequency Online UPS 6K - 10kVA
Cold Start Function 1pH in/1pH out High Frequency Online UPS 6K - 10kVA
Cold Start Function 1pH in/1pH out High Frequency Online UPS 6K - 10kVA
Cold Start Function 1pH in/1pH out High Frequency Online UPS 6K - 10kVA
Cold Start Function 1pH in/1pH out High Frequency Online UPS 6K - 10kVA
Cold Start Function 1pH in/1pH out High Frequency Online UPS 6K - 10kVA
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now