80kVA / 64kw Online UPS with Surge Protection and Short Circuit Protection

Product Details
Customization: Available
Phase: Three Phase
Type: On-line
Diamond Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Plant Area
>2000 square meters
Management System Certification
ISO 9001, ISO 14001
Find Similar Products

Basic Info.

Model NO.
33Q80KL
Protection
Short Circuit
Application
Industry
Classification
Lighting/Power
Standby Time
Long-acting Machine
Standby UPS
Sine Wave Output UPS
Output Capacity
Large Type
Equipment Mode
Decentralized
Power Factor
Above 0.99
Thdi
Less 5%
Frequency
40-70Hz
Voltage Precision
±0.5%
Transport Package
Carton/Pallet
Specification
CE & ISO Certificate
Trademark
UPSEN
Origin
China
HS Code
8504402000
Production Capacity
3000 PCS/Mounth

Product Description


Online UPS Queen Star Series 10K-80KVA  (3ph in/3ph out)

Key Features
True double-conversion.
DSP technology guarantees high performance.
Output power factor 0.8.
Active power factor correction in all phases.
50Hz/60Hz frequency converter mode.
Accepts dual-mains inputs.
Generator compatible.
SNMP+USB+RS-232 multiple communications.
3-stage extendable charging design for optimized battery performance.
Adjustable battery numbers.
Maintenance bypass available.
Optional N+X parallel redundancy.
 
Model 33Q10KL 33Q 20KL 33Q 30KL 33Q 40KL 33Q 60KL 33Q 80KL Comments
Input
Input voltage
Rated voltage 380VAC/220VAC 380VAC  
Phase three phase with ground  
Turn on voltage range (120±5~274±5)VAC (207±9~475±9)VAC  
Bypass voltage range (60±5~300±5)VAC (105±9~518±9)VAC Could be adjusted by software.
Bypass
low loss
60VAC~220VAC(default 60VAC) 105VAC~380VAC
(default 105VAC)
 
Bypass low comeback Low loss +5VAC Low loss +17VAC  
Bypass high loss 220VAC~300VAC(default 300VAC) 380VAC~475VAC
(default 475VAC)
 
Bypass high comeback High loss -5VAC High loss -17VAC  
Line low loss
/comeback
(120±5) VAC /(140±5) VAC (207±9) VAC /(242±9)VAC load≤50%
(140±5) VAC /(160±5) VAC (242±9) VAC /(276±9)VAC 50%<load ≤90%
(160±5) VAC /(175±5) VAC (276±9) VAC /(302±9)VAC load>90%
Line high loss/comeback (275±5)VAC/(260±5)VAC (475±9)VAC/(449±9)VAC  
Input frequency
Rated frequency 50Hz  
Frequency
low loss
(40~49) ±0.2Hz(default:46Hz) Could be adjusted by software.
Frequency
low comeback
Frequency low loss +0.5Hz
Frequency
high loss
(51~60)±0.2Hz(default:54Hz)
Frequency high comeback Frequency high loss -0.5Hz
Input power factor
Input power factor > 0.99 33Q 10-40KL:220VAC,full R load
33Q 60-80KL: 380VAC,full R load
Generator Support generator input Generator rating≥2*UPS rating
Input current
Rated current 14A 28A 42A 67A 80A 105A  
Input THDI <= 10%  
Output protection
Rating protection 32A
Breaker
50A
Breaker
60A
Breaker
80A
Breaker
100A
Breaker
125A
Breaker
 
Output power
VA/watt 10KVA/8KW 20KVA/16KW 30KVA/24KW 40KVA/32KW 60KVA/
48KW
80KVA/
64KW
 
Rated voltage 220VAC 380VAC Sine wave
Voltage range 200/208/220/230/240VAC 345/359/380/397/415 VAC 33Q 10-40KL: Could be adjusted by software. 10% derating for 208VAC/200VAC.
33Q 60-80KL: Could be adjusted by software. 10% derating for 345VAC/359VAC.
Voltage regulation ±1%  
Voltage distortion ≤5% ≤10% Full RCD load
≤3% Full R load
DC offset ≤200mV  
Transient response ≤9% R load 0%~100%~0%
≤6% R load 20%~100%~20%
Transient recovery ≤60ms voltage recovery to 90% Full RCD load
Bypass output
before turn-on
YES  
Crest ration 3:1  
Output frequency range
Normal mode 1,Same as input frequency(46Hz~54Hz)
2,50Hz(Input frequency>54Hz or Input frequency<46Hz)
 
Battery mode (50±0.1) Hz  
Slew rate 1 Hz/Sec  
Efficiency
Normal  mode > 93% > 90%  
Battery mode > 90% > 90%  
Overload
Normal mode
/battery mode
Overload warning only 105%±5%≤load
1min,then transfer to bypass and alarm. 105%±5%
30S,then transfer to bypass and alarm. 125%±5%
300mS, then transfer to bypass and alarm. load>150%±5%
Automatically retransfer YES  
Short protection
Normal/
battery mode
YES  
Transfer time
Normal to battery mode 0mS  
Battery to normal mode 0mS  
Normal to bypass mode <4mS 0mS  
Bypass to normal mode <4mS 0mS  
Battery and charger
Battery
Rated voltage 192VDC 240VDC 192VDC*2 192VDC*2 480VDC  
Type/Rating            
Battery quantity 16 20 16*2 16*2 40  
Backup time            
Protection
Low alarm voltage /comebackvoltage (180.8V±4V)/ (188.8V±4V) (226V±4V)/ (236V±4V) (180.8V±4V)/ (188.8V±4V) (226V±4V)/ (236V±4V) (452V±4V)/ (472V±4V) 33Q 30KL use two
Shutdown voltage/ comeback voltage 160V±4V/168V±4V (200V±4V)/ (210V±4V) 160V±4V/
168V±4V
(200V±4V)/ (210V±4V) (400V±4V)/ (420V±4V)  
DC protection
Overcharge protection/ comeback voltage (249.6V±4V)/
(216V±4V)
(312V±4V) (270V±4V) (249.6V±4V)/ (216V±4V) (312V±4V) (270V±4V) (624V±4V) (540V±4V)  
Leakage current < 500uA  
Over discharge protection 14.5h   Could be set by software
Battery test
Battery weak YES  
Battery fault YES  
Charger
Output voltage (219.2±3)VDC (277±3)VDC (219.2±3)VDC (277±3)VDC (554±3)VDC  
Charge time Depends on the external battery capacity  
Charge current 7.5A 6A 5A 4A 10A  
Interface
Alarm silence YES  
DC power
turn-on
YES  
Automatically retransfer YES  
Audio alarm
Battery mode Beep/4s  
Battery low/
charger fault
Beep/1s  
UPS fault Continue beep  
Overload Beep/1s  
Bypass mode Beep/2Min  
L/N inverse Beep/2Min  
Communication
RS232 interface YES  
Intelligent slot YES  
Monitor software Appending with UPS  
Cooling
Force air cooling  
Display
LCD/LED displays UPS status
Environment
Work temperature 0ºC~40ºC  
Altitude <1000m  
Audible noise ≤60dB  
Storage temperature -15ºC~45ºC  
Work humidity 20%~95%  
Standard
EMS
ESD IEC61000-4-2 Level4
RS IEC61000-4-3 Level3
EFT IEC61000-4-4 Level4
Surge IEC61000-4-5 Level4
EMI
Conducted EN55022 Class A
Radiated EN55022 Class A
Safety
Safety GB4943-2001/IEC62040-1  
Machinery features
Size
Outline dimension and net weight
L*W*H (mm) 710*260*717 840*515*1135  
Net weight(Kg) 45/93 50/98     195 208  
Optional functions
60Hz     Optional Set by software
Converter mode     Optional Set by software
ECO Optional Optional Available and set by software
EPO Optional Optional  
*Specification is subject to change without further notice

80kVA / 64kw Online UPS with Surge Protection and Short Circuit Protection
80kVA / 64kw Online UPS with Surge Protection and Short Circuit Protection


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier