Product Highlights

  • True Double Conversion: DSP technology ensures high performance with active power factor correction in all phases.
  • Parallel Redundancy: Optional N+X parallel redundancy function for enhanced system reliability and scalability.
  • Smart Communication: Integrated SNMP, USB, and RS-232 ports for intelligent monitoring and battery management.
  • Flexible Input: Accepts dual-mains inputs and is generator compatible with adjustable frequency modes.
  • High Efficiency: Normal mode efficiency exceeds 93%, ensuring optimal energy usage and performance.
  • Zero Transfer Time: 0ms transfer time between normal and battery modes for seamless power protection.
  • Adjustable Battery: 3-stage extendable charging design with adjustable battery numbers for optimized performance.
  • Wide Voltage Range: Supports 380V/400V/415VAC input and output with software-adjustable voltage settings.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of Online UPS with Double Conversion Technology - Parallel Function, USB & Smart BMS Integration

Online UPS with Double Conversion Technology - Parallel Function, USB & Smart BMS Integration
Online UPS with Double Conversion Technology - Parallel Function, USB & Smart BMS Integration pictures & photos
Online UPS with Double Conversion Technology - Parallel Function, USB & Smart BMS Integration
Online UPS with Double Conversion Technology - Parallel Function, USB & Smart BMS Integration pictures & photos
Online UPS with Double Conversion Technology - Parallel Function, USB & Smart BMS Integration
Online UPS with Double Conversion Technology - Parallel Function, USB & Smart BMS Integration pictures & photos
Online UPS with Double Conversion Technology - Parallel Function, USB & Smart BMS Integration
Online UPS with Double Conversion Technology - Parallel Function, USB & Smart BMS Integration pictures & photos
Online UPS with Double Conversion Technology - Parallel Function, USB & Smart BMS Integration
Online UPS with Double Conversion Technology - Parallel Function, USB & Smart BMS Integration pictures & photos
Online UPS with Double Conversion Technology - Parallel Function, USB & Smart BMS Integration
Online UPS with Double Conversion Technology - Parallel Function, USB & Smart BMS Integration pictures & photos
Online UPS with Double Conversion Technology - Parallel Function, USB & Smart BMS Integration
  • Online UPS with Double Conversion Technology - Parallel Function, USB & Smart BMS Integration
  • Online UPS with Double Conversion Technology - Parallel Function, USB & Smart BMS Integration
    Online UPS with Double Conversion Technology - Parallel Function, USB & Smart BMS Integration
  • Online UPS with Double Conversion Technology - Parallel Function, USB & Smart BMS Integration
    Online UPS with Double Conversion Technology - Parallel Function, USB & Smart BMS Integration
  • Online UPS with Double Conversion Technology - Parallel Function, USB & Smart BMS Integration
    Online UPS with Double Conversion Technology - Parallel Function, USB & Smart BMS Integration
  • Online UPS with Double Conversion Technology - Parallel Function, USB & Smart BMS Integration
    Online UPS with Double Conversion Technology - Parallel Function, USB & Smart BMS Integration
  • Online UPS with Double Conversion Technology - Parallel Function, USB & Smart BMS Integration
    Online UPS with Double Conversion Technology - Parallel Function, USB & Smart BMS Integration
  • Online UPS with Double Conversion Technology - Parallel Function, USB & Smart BMS Integration
    Online UPS with Double Conversion Technology - Parallel Function, USB & Smart BMS Integration

Find Similar Products

Product Description

Double Conversion Online UPS with USB Port and Parallel Redundancy Function for Intelligent Battery Management System 

Quick View
1: China UPS with good quality and low price, same quality like APC, MGE UPS.
2: 3 Phase UPS with 50Hz / 60Hz Frequency and 380V / 400V / 415VAC Input and output
3: Triphase UPS with Emergency power off function (EPO)
3: UPS with SNMP , USB , RS232 Ports
4: UPS with Parallel Redundancy Function


UPS Key Features  

  • True double-conversion.
  • DSP technology guarantees high performance.
  • Output power factor 0.8.
  • Active power factor correction in all phases.
  • 50Hz/60Hz frequency converter mode.
  • Accepts dual-mains inputs.
  • Generator compatible.
  • SNMP+USB+RS-232 multiple communications.
  • 3-stage extendable charging design for optimized battery performance.
  • Adjustable battery numbers.
  • Maintenance bypass available.
  • Optional N+X parallel redundancy.
Technical Specification
Model 33Q10KL 33Q 20KL 33Q 30KL 33Q 40KL 33Q 60KL 33Q 80KL Comments
Input
Input voltage
Rated voltage 380VAC/220VAC 380VAC  
Phase three phase with ground  
Turn on voltage range (120±5~274±5)VAC (207±9~475±9)VAC  
Bypass voltage range (60±5~300±5)VAC (105±9~518±9)VAC Could be adjusted by software.
Bypass
low loss
60VAC~220VAC(default 60VAC) 105VAC~380VAC
(default 105VAC)
 
Bypass low comeback Low loss +5VAC Low loss +17VAC  
Bypass high loss 220VAC~300VAC(default 300VAC) 380VAC~475VAC
(default 475VAC)
 
Bypass high comeback High loss -5VAC High loss -17VAC  
Line low loss
/comeback
(120±5) VAC /(140±5) VAC (207±9) VAC /(242±9)VAC load≤50%
(140±5) VAC /(160±5) VAC (242±9) VAC /(276±9)VAC 50%<load ≤90%
(160±5) VAC /(175±5) VAC (276±9) VAC /(302±9)VAC load>90%
Line high loss/comeback (275±5)VAC/(260±5)VAC (475±9)VAC/(449±9)VAC  
Input frequency
Rated frequency 50Hz  
Frequency
low loss
(40~49) ±0.2Hz(default:46Hz) Could be adjusted by software.
Frequency
low comeback
Frequency low loss +0.5Hz
Frequency
high loss
(51~60)±0.2Hz(default:54Hz)
Frequency high comeback Frequency high loss -0.5Hz
Input power factor
Input power factor > 0.99 33Q 10-40KL:220VAC,full R load
33Q 60-80KL: 380VAC,full R load
Generator Support generator input Generator rating≥2*UPS rating
Input current
Rated current 14A 28A 42A 67A 80A 105A  
Input THDI <= 10%  
Output protection
Rating protection 32A
Breaker
50A
Breaker
60A
Breaker
80A
Breaker
100A
Breaker
125A
Breaker
 
Output power
VA/watt 10KVA/8KW 20KVA/16KW 30KVA/24KW 40KVA/32KW 60KVA/
48KW
80KVA/
64KW
 
Rated voltage 220VAC 380VAC Sine wave
Voltage range 200/208/220/230/240VAC 345/359/380/397/415 VAC 33Q 10-40KL: Could be adjusted by software. 10% derating for 208VAC/200VAC.
33Q 60-80KL: Could be adjusted by software. 10% derating for 345VAC/359VAC.
Voltage regulation ±1%  
Voltage distortion ≤5% ≤10% Full RCD load
≤3% Full R load
DC offset ≤200mV  
Transient response ≤9% R load 0%~100%~0%
≤6% R load 20%~100%~20%
Transient recovery ≤60ms voltage recovery to 90% Full RCD load
Bypass output
before turn-on
YES  
Crest ration 3:1  
Output frequency range
Normal mode 1,Same as input frequency(46Hz~54Hz)
2,50Hz(Input frequency>54Hz or Input frequency<46Hz)
 
Battery mode (50±0.1) Hz  
Slew rate 1 Hz/Sec  
Efficiency
Normal  mode > 93% > 90%  
Battery mode > 90% > 90%  
Overload
Normal mode
/battery mode
Overload warning only 105%±5%≤load
1min,then transfer to bypass and alarm. 105%±5%
30S,then transfer to bypass and alarm. 125%±5%
300mS, then transfer to bypass and alarm. load>150%±5%
Automatically retransfer YES  
Short protection
Normal/
battery mode
YES  
Transfer time
Normal to battery mode 0mS  
Battery to normal mode 0mS  
Normal to bypass mode <4mS 0mS  
Bypass to normal mode <4mS 0mS  
Battery and charger
Battery
Rated voltage 192VDC 240VDC 192VDC*2 192VDC*2 480VDC  
Type/Rating            
Battery quantity 16 20 16*2 16*2 40  
Backup time            
Protection
Low alarm voltage /comebackvoltage (180.8V±4V)/ (188.8V±4V) (226V±4V)/ (236V±4V) (180.8V±4V)/ (188.8V±4V) (226V±4V)/ (236V±4V) (452V±4V)/ (472V±4V) 33Q 30KL use two
Shutdown voltage/ comeback voltage 160V±4V/168V±4V (200V±4V)/ (210V±4V) 160V±4V/
168V±4V
(200V±4V)/ (210V±4V) (400V±4V)/ (420V±4V)  
DC protection
Overcharge protection/ comeback voltage (249.6V±4V)/
(216V±4V)
(312V±4V) (270V±4V) (249.6V±4V)/ (216V±4V) (312V±4V) (270V±4V) (624V±4V) (540V±4V)  
Leakage current < 500uA  
Over discharge protection 14.5h   Could be set by software
Battery test
Battery weak YES  
Battery fault YES  
Charger
Output voltage (219.2±3)VDC (277±3)VDC (219.2±3)VDC (277±3)VDC (554±3)VDC  
Charge time Depends on the external battery capacity  
Charge current 7.5A 6A 5A 4A 10A  
Interface
Alarm silence YES  
DC power
turn-on
YES  
Automatically retransfer YES  
Audio alarm
Battery mode Beep/4s  
Battery low/
charger fault
Beep/1s  
UPS fault Continue beep  
Overload Beep/1s  
Bypass mode Beep/2Min  
L/N inverse Beep/2Min  
Communication
RS232 interface YES  
Intelligent slot YES  
Monitor software Appending with UPS  
Cooling
Force air cooling  
Display
LCD/LED displays UPS status
Environment
Work temperature 0ºC~40ºC  
Altitude <1000m  
Audible noise ≤60dB  
Storage temperature -15ºC~45ºC  
Work humidity 20%~95%  
Standard
EMS
ESD IEC61000-4-2 Level4
RS IEC61000-4-3 Level3
EFT IEC61000-4-4 Level4
Surge IEC61000-4-5 Level4
EMI
Conducted EN55022 Class A
Radiated EN55022 Class A
Safety
Safety GB4943-2001/IEC62040-1  
Machinery features
Size
Outline dimension and net weight
L*W*H (mm) 710*260*717 840*515*1135  
Net weight(Kg) 45/93 50/98     195 208  
Optional functions
60Hz     Optional Set by software
Converter mode     Optional Set by software
ECO Optional Optional Available and set by software
EPO Optional Optional  
*Specification is subject to change without further notice

Online UPS with Double Conversion Technology - Parallel Function, USB &amp; Smart BMS Integration



Online UPS with Double Conversion Technology - Parallel Function, USB &amp; Smart BMS Integration

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR2521484". Items marked "verified" are certified.

Watch Video
Watch Video
Shenzhen UPSEN Electronic Co., Ltd.
Shenzhen UPSEN Electronic Co., Ltd.
Shenzhen UPSEN Electronic Co., Ltd.
Shenzhen UPSEN Electronic Co., Ltd.
Shenzhen UPSEN Electronic Co., Ltd.
Shenzhen UPSEN Electronic Co., Ltd.
Shenzhen UPSEN Electronic Co., Ltd.
Shenzhen UPSEN Electronic Co., Ltd.

About Our Factory & Business Background

Address
1409-1410, Tongfang Center, The Intersection of Zhongxin Rd. and Haoxiang Rd., Xinqiao St., Bao'an Dist, Shenzhen, Guangdong, China
Terms of Payment
LC, T/T, PayPal, Western Union, Money Gram
International Commercial Terms(Incoterms)
CFR, CIF, CIP, EXW
Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Nearest Port
Shenzhen

Our Production Capability & Technical Expertise

Main Products
UPS, Inverter, Battery, Energy Storage, Solar Power, UPS Power, Portable Power Station, Online UPS, Power Inverter, DC AC Inverter

Our Industry Experience & Global Business Record

Export Year
2009-04-08
Main Markets
North America, South America, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What is the transfer time between normal and battery modes?
The transfer time is 0ms for both normal to battery mode and battery to normal mode transitions.
Does this UPS support parallel redundancy?
Yes, optional N+X parallel redundancy functions are available for enhanced system reliability.
What communication interfaces are supported?
The UPS supports SNMP, USB, and RS-232 interfaces for intelligent monitoring and management.
Is the UPS compatible with generators?
Yes, the UPS is generator compatible and accepts dual-mains inputs for flexible power sources.
What is the efficiency in normal mode?
The efficiency in normal mode exceeds 93%, ensuring high energy performance.
Can the battery configuration be adjusted?
Yes, the UPS features a 3-stage extendable charging design with adjustable battery numbers.
What is the input voltage range?
The UPS accepts 380V/400V/415VAC input and output, with software-adjustable voltage settings.
What is the power factor correction feature?
It features active power factor correction in all phases, ensuring high performance and efficiency.