Double Conversion Online UPS with USB Port and Parallel Function for Intelligent BMS

Phase: Three Phase
Type: On-line
Protection: Over Load/ Current/Voltage, Short Circuit
Application: Communication
Classification: Lighting/Power
Standby UPS: Sine Wave Output UPS
Customization:
Diamond Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
Queen Star Series
Output Capacity
Medium Type
Brand
Upsen or OEM
RS232/Snmp
Support
Battery
Internal/External
Cold Start
Available
Transfer Time
0ms
Support Generator Input
Yes
Transport Package
Cartons & Wooden Pallet
Specification
CE & ISO&RoHS Certificate
Trademark
UPSEN or OEM
Origin
China
HS Code
8504402000
Production Capacity
50, 000PCS/Month

Product Description

Double Conversion Online UPS with USB Port and Parallel Redundancy Function for Intelligent Battery Management System 

Quick View
1: China UPS with good quality and low price, same quality like APC, Eaton, MGE UPS.
2: 3 Phase UPS with 50Hz / 60Hz Frequency and 380V / 400V / 415VAC Input and output
3: Triphase UPS with Emergency power off function (EPO)
3: UPS with SNMP , USB , RS232 Ports
4: UPS with Parallel Redundancy Function


UPS Key Features  

  • True double-conversion.
  • DSP technology guarantees high performance.
  • Output power factor 0.8.
  • Active power factor correction in all phases.
  • 50Hz/60Hz frequency converter mode.
  • Accepts dual-mains inputs.
  • Generator compatible.
  • SNMP+USB+RS-232 multiple communications.
  • 3-stage extendable charging design for optimized battery performance.
  • Adjustable battery numbers.
  • Maintenance bypass available.
  • Optional N+X parallel redundancy.
Technical Specification
Model 33Q10KL 33Q 20KL 33Q 30KL 33Q 40KL 33Q 60KL 33Q 80KL Comments
Input
Input voltage
Rated voltage 380VAC/220VAC 380VAC  
Phase three phase with ground  
Turn on voltage range (120±5~274±5)VAC (207±9~475±9)VAC  
Bypass voltage range (60±5~300±5)VAC (105±9~518±9)VAC Could be adjusted by software.
Bypass
low loss
60VAC~220VAC(default 60VAC) 105VAC~380VAC
(default 105VAC)
 
Bypass low comeback Low loss +5VAC Low loss +17VAC  
Bypass high loss 220VAC~300VAC(default 300VAC) 380VAC~475VAC
(default 475VAC)
 
Bypass high comeback High loss -5VAC High loss -17VAC  
Line low loss
/comeback
(120±5) VAC /(140±5) VAC (207±9) VAC /(242±9)VAC load≤50%
(140±5) VAC /(160±5) VAC (242±9) VAC /(276±9)VAC 50%<load ≤90%
(160±5) VAC /(175±5) VAC (276±9) VAC /(302±9)VAC load>90%
Line high loss/comeback (275±5)VAC/(260±5)VAC (475±9)VAC/(449±9)VAC  
Input frequency
Rated frequency 50Hz  
Frequency
low loss
(40~49) ±0.2Hz(default:46Hz) Could be adjusted by software.
Frequency
low comeback
Frequency low loss +0.5Hz
Frequency
high loss
(51~60)±0.2Hz(default:54Hz)
Frequency high comeback Frequency high loss -0.5Hz
Input power factor
Input power factor > 0.99 33Q 10-40KL:220VAC,full R load
33Q 60-80KL: 380VAC,full R load
Generator Support generator input Generator rating≥2*UPS rating
Input current
Rated current 14A 28A 42A 67A 80A 105A  
Input THDI <= 10%  
Output protection
Rating protection 32A
Breaker
50A
Breaker
60A
Breaker
80A
Breaker
100A
Breaker
125A
Breaker
 
Output power
VA/watt 10KVA/8KW 20KVA/16KW 30KVA/24KW 40KVA/32KW 60KVA/
48KW
80KVA/
64KW
 
Rated voltage 220VAC 380VAC Sine wave
Voltage range 200/208/220/230/240VAC 345/359/380/397/415 VAC 33Q 10-40KL: Could be adjusted by software. 10% derating for 208VAC/200VAC.
33Q 60-80KL: Could be adjusted by software. 10% derating for 345VAC/359VAC.
Voltage regulation ±1%  
Voltage distortion ≤5% ≤10% Full RCD load
≤3% Full R load
DC offset ≤200mV  
Transient response ≤9% R load 0%~100%~0%
≤6% R load 20%~100%~20%
Transient recovery ≤60ms voltage recovery to 90% Full RCD load
Bypass output
before turn-on
YES  
Crest ration 3:1  
Output frequency range
Normal mode 1,Same as input frequency(46Hz~54Hz)
2,50Hz(Input frequency>54Hz or Input frequency<46Hz)
 
Battery mode (50±0.1) Hz  
Slew rate 1 Hz/Sec  
Efficiency
Normal  mode > 93% > 90%  
Battery mode > 90% > 90%  
Overload
Normal mode
/battery mode
Overload warning only 105%±5%≤load
1min,then transfer to bypass and alarm. 105%±5%
30S,then transfer to bypass and alarm. 125%±5%
300mS, then transfer to bypass and alarm. load>150%±5%
Automatically retransfer YES  
Short protection
Normal/
battery mode
YES  
Transfer time
Normal to battery mode 0mS  
Battery to normal mode 0mS  
Normal to bypass mode <4mS 0mS  
Bypass to normal mode <4mS 0mS  
Battery and charger
Battery
Rated voltage 192VDC 240VDC 192VDC*2 192VDC*2 480VDC  
Type/Rating            
Battery quantity 16 20 16*2 16*2 40  
Backup time            
Protection
Low alarm voltage /comebackvoltage (180.8V±4V)/ (188.8V±4V) (226V±4V)/ (236V±4V) (180.8V±4V)/ (188.8V±4V) (226V±4V)/ (236V±4V) (452V±4V)/ (472V±4V) 33Q 30KL use two
Shutdown voltage/ comeback voltage 160V±4V/168V±4V (200V±4V)/ (210V±4V) 160V±4V/
168V±4V
(200V±4V)/ (210V±4V) (400V±4V)/ (420V±4V)  
DC protection
Overcharge protection/ comeback voltage (249.6V±4V)/
(216V±4V)
(312V±4V) (270V±4V) (249.6V±4V)/ (216V±4V) (312V±4V) (270V±4V) (624V±4V) (540V±4V)  
Leakage current < 500uA  
Over discharge protection 14.5h   Could be set by software
Battery test
Battery weak YES  
Battery fault YES  
Charger
Output voltage (219.2±3)VDC (277±3)VDC (219.2±3)VDC (277±3)VDC (554±3)VDC  
Charge time Depends on the external battery capacity  
Charge current 7.5A 6A 5A 4A 10A  
Interface
Alarm silence YES  
DC power
turn-on
YES  
Automatically retransfer YES  
Audio alarm
Battery mode Beep/4s  
Battery low/
charger fault
Beep/1s  
UPS fault Continue beep  
Overload Beep/1s  
Bypass mode Beep/2Min  
L/N inverse Beep/2Min  
Communication
RS232 interface YES  
Intelligent slot YES  
Monitor software Appending with UPS  
Cooling
Force air cooling  
Display
LCD/LED displays UPS status
Environment
Work temperature 0ºC~40ºC  
Altitude <1000m  
Audible noise ≤60dB  
Storage temperature -15ºC~45ºC  
Work humidity 20%~95%  
Standard
EMS
ESD IEC61000-4-2 Level4
RS IEC61000-4-3 Level3
EFT IEC61000-4-4 Level4
Surge IEC61000-4-5 Level4
EMI
Conducted EN55022 Class A
Radiated EN55022 Class A
Safety
Safety GB4943-2001/IEC62040-1  
Machinery features
Size
Outline dimension and net weight
L*W*H (mm) 710*260*717 840*515*1135  
Net weight(Kg) 45/93 50/98     195 208  
Optional functions
60Hz     Optional Set by software
Converter mode     Optional Set by software
ECO Optional Optional Available and set by software
EPO Optional Optional  
*Specification is subject to change without further notice

Double Conversion Online UPS with USB Port and Parallel Function for Intelligent BMS



Double Conversion Online UPS with USB Port and Parallel Function for Intelligent BMS

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now