Double Conversion Online UPS 10k-30kVA with Long Backup Time

Phase: Three Phase
Type: On-line
Protection: Overvoltage
Application: Fire Safety
Classification: Lighting/Power
Standby Time: Long-acting Machine
Samples:
US$ 100/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
View Star Series
Standby UPS
Sine Wave Output UPS
Output Capacity
Large Type
Equipment Mode
Decentralized
Nominal Voltage
3 X 400 VAC (3pH+N)
Current Crest Ratio
3:1 (Max)
Waveform
Pure Sine Wave
Battery Type
12 V / 9 Ah
Transfer Time
0 Ms
Frequency
High
Transport Package
Cartons & Wooden Pallet
Specification
CE & ISO Certificate
Trademark
UPSEN
Origin
China
HS Code
8504402000
Production Capacity
50, 000PCS/Month

Product Description

Double Conversion Online UPS 10k-30kVA with long backup time

Quick Read
1: UPS with 3 Phase 380 / 400 /415Vac Input and 220 / 230 / 240Vac Output
2: Standard emergency power off (EPO)
3: UPS with long backup time
4: UPS with online double-conversion DSP control
5: UPS with IGBT rectifier and high input power factor(>0.99)
 
Key Features    
1)Intelligent detecting function  
2)DC emergency start function
3)Active input power factor correction 0.99
4)Zero switching time, pure sine wave output
5)Optional Remote Emergency Power Off (REPO)
6)Inverter IGBT technology with high frequency communication
7)Pure sine wave output, true on-line dual conversion design
8)Double conversion on-line design, including output isolation transformer
9)with temperature control function, which can save energy consumption
10)Module structure consisting of 1 to 12 power modules, one static switch module and one system monitor module, which are connected in parallel
11)3 phase pure sine wave ups adopts full digitalized dsp-based Ti high performance micro-processor control for reliability
   
Applications:
Servers, Data-center, critical network devices, Sensitive electronic equipment, Control Equipment,Medical Systems etc.
 
Technical Specification
VIEW STAR SERIES ONLINE UPS SELECTION GUIDE
MODEL VS31 10K (L)  VS31 15K (L)  VS31 20K (L) VS31 30K (L)
PHASE 3 phase in / 1 phase out
CAPACITY 10000 VA / 8000 W 15000 VA/12000 W 20000 VA/16000 W 30000VA/24000W
INPUT

 


 
Nominal Voltage 3 x 400 VAC (3Ph+N)
Voltage Range 305-478 VAC (3-phase) @ 100% load
190-520 VAC (3-phase) @ 50% load 
Frequency Range 46~54 Hz or 56~64Hz
Power Factor >= 0.99  @ 100% load
OUTPUT
Output Voltage 208/220/230/240VAC
AC Voltage Regulation                   (Batt. Mode) ± 1%
Frequency Range                (Synchronized Range) 46~54 Hz 50 Hz / 56~64 Hz 60 Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio 3:1 (Max)
Harmonic Distortion Less than 2 % THD (Linear Load)
Less than 5 % THD (Non-linear Load
Transfer Time AC Mode to Batt. Mode zero
Inverter to Bypass zero
Waveform (Batt. Mode) Pure Sine Wave
EFFICIENCY
AC Mode 89% 89% 89% 80%
Battery Mode 86% 88% 87% 89%
BATTERY




Standard Model
Battery Type 12 V / 9 AH
Numbers 16 pcs 16 pcs x 2 strings 16 pcs x 3 strings
Typical Recharge Time 9 hours recover to 90% capacity
Charging Current (max.) 1A 2A 2A 2A
Charging Voltage  273 VDC ± 1%(based on 20 pcs batteries)




Long-run Model
Battery Type Depending on the capacity of external batteries
Numbers 16pcs(192V) 16pcs(192V) 16pcs(192V) 20pcs(240V)        (18-20adjustable)
Charging Current (max.) 4A 4A 4A 12A
Charging Voltage 273 VDC ± 1%(based on 20 pcs batteries)
INDICATORS
LCD Panel UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
ALARM
Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continuously sounding
PHYSICAL




Standard Model




Dimension,                        D X W X H (mm)




592 X 250 X 576




815 x 250 x 826




815*300*1000




Net Weight (kgs)




83




164




234




Long-run Model




Dimension,                        D X W X H (mm)




592 X 250 X 576




592 X 250 X 576




815 x 250 x 826




Net Weight (kgs)




28




40




64
ENVIRONMENT
Operation Humidity 0-95 % RH @ 0- 40°C (non-condensing)




Noise Level




Less than 58dB @      1 Meter




Less than 60dB @ 1 Meter




Less than 65dB @  1 Meter
MANAGEMENT
Smart RS-232 Supports Windows® 2000/2003/XP/Vista/2008, Windows®  7/8, Linux, Unix, and MAC
USB
Optional SNMP Power management from SNMP manager and web browser
* Long-run model is only available in 200/208/220/230/240VAC systems.
 
Competitive Advantages:
1: Three Years' warranty for Online UPS, and 1% free UPS or 2% free PCB Boards
2: Good after-sales service, we will be full responsible for any faults caused by our side
3: Professional experience in power field more than 10 years
4: Professional technical support before and after sales                                              
5: Timely response, fast delivery time and flexible operations to satisfy any customers' special requests.   
6: Free OEM & ODM Service                                       
7: Competitive price, quality and mature products

Double Conversion Online UPS 10k-30kVA with Long Backup Time
Double Conversion Online UPS 10k-30kVA with Long Backup Time
Double Conversion Online UPS 10k-30kVA with Long Backup Time
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now