Guangdong, China
Business Type:
Manufacturer/Factory
Plant Area:
>2000 square meters
Management System Certification:
ISO 9001, ISO 14001
OEM/ODM Availability:
Yes
OEM/ODM Service
Sample Available
Overseas Agent / Branch

High Frequency Online UPS, Online UPS, High Reliability Online UPS manufacturer / supplier in China, offering 3 X 400 VAC High Reliability Online High Frequency UPS, Double Conversion UPS Online 1000va 2000va 3000va with Eco Mode and 93% High Efficiency, Pure Sine Wave Inverter with AC Battery Charger and UPS Function and so on.

Gold Member Since 2014
Audited Supplier

3 X 400 VAC High Reliability Online High Frequency UPS

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $1-1,000/ Piece
Port: Shenzhen, China
Production Capacity: 50, 000PCS/Month
Payment Terms: L/C, T/T, Western Union, Money Gram
Phase: Three Phase
Type: On-line
Protection: Overvoltage
Application: Fire Safety
Classification: Lighting/Power
Standby Time: Long-acting Machine

You Might Also Like

Loading...

Basic Info

Model NO.: Queen Star Plus 33Q10K-80K
Standby UPS: Sine Wave Output UPS
Output Capacity: Large Type
Equipment Mode: Decentralized
Brand: Upsen
True Double-Conversion: Yes
Self-Test: Yes
Frequency: 50Hz/60Hz
Communications: Snmp/USB/RS-232
Trademark: UPSEN
Transport Package: Cartons & Wooden Pallet
Specification: CE & ISO Certificate
Origin: China
HS Code: 8504402000

Product Description

3 x 400 VACHigh reliability Online High Frequency UPS 
High Frequency Online UPS Queen Star Plus Strar Series 33Q10K-80K(3Ph in/3Ph out)

Key Features 
   
1:Self-test when UPS start
2:Power management software  
3:True double-conversion on line UPS
4:UPS with 80% more life than before
5:SNMP/USB/RS-232 communications
6:50Hz/60Hz frequency converter mode
7:Programmable power management outlets
8:DSP technology guarantees high performance  
9:Microprocessor control guarantees high reliability 
10:3-stage extendable charging design for optimized battery performance

   
Applications:
Computer center,Network center,Communication system,Education System,Medical Equipment,Financial System or other critical systems etc.
 
Technical Specification:
Index33Q 10KL33Q 20KL33Q 30KL33Q 40KL 33Q 60KL 33Q 80KLComments
Input
Input voltage
Rated voltage380VAC/220VAC380VAC 
Phasethree phase with ground 
Turn on 
voltage range
(120±5~274±5)VAC(207±9~475±9)
VAC
 
Bypass 
voltage range
(60±5~300±5)VAC(105±9~518±9)
VAC
Could be 
adjusted 
by software.
Bypass 
low loss
60VAC~220VAC(default 60VAC)105VAC~380VAC
(default 105VAC)
 
Bypass
 low comeback
Low loss +5VACLow loss 
+17VAC
 
Bypass 
high loss
220VAC~300VAC(default 300VAC)380VAC~475VAC
(default 475VAC)
 
Bypass 
high comeback
High loss -5VACHigh loss -17VAC 
Line low loss
comeback
(120±5) VAC /(140±5) VAC(207±9) VAC 
(242±9) VAC
load≤50%
(140±5) VAC /(160±5) VAC(242±9) VAC
(276±9) VAC
50%≤90%
(160±5) VAC /(175±5) VAC(276±9) VAC
(302±9) VAC
load>90%
Line high loss
comeback
(275±5)VAC/(260±5)VAC(475±9)VAC
(449±9)VAC
 
Input frequency
Rated 
frequency
50Hz 
Frequency 
low loss
(40~49) ±0.2Hz(default:46Hz)Could be 
adjusted
 by software.
Frequency 
low comeback
Frequency low loss +0.5Hz
Frequency 
high loss
(51~60)±0.2Hz(default:54Hz)
Frequency 
high comeback
Frequency high loss -0.5Hz
Input power factor
Could be 
adjusted 
by software.
> 0.9933Q 10-40KL:
220VAC,full R load
33Q 60-80KL: 
380VAC,full R load
Generator Support generator inputGenerator rating
≥2*UPS rating
Input current
Rated current 14A28A42A67A80A105A 
Input THDI<= 10% 
Output protection
Rating 
protection
32A 
Breaker
50A 
Breaker
60A 
Breaker
80A 
Breaker
100A 
Breaker
125A 
Breaker
 
Output power
VA/watt10KVA/8KW20KVA/16KW30KVA/24KW40KVA/32KW60KVA/
48KW
80KVA/
64KW
 
Rated voltage220VAC380VACSine wave
Voltage range200/208/220
/230/240VAC
345/359/380
/397/415 VAC
33Q 10-40KL: 
Could be 
adjusted 
by software. 
10% derating 
for 
208VAC
/200VAC.
33Q 60-80KL: 
Could be 
adjusted 
by software. 
10% derating 
for 345VAC
/359VAC.
Voltage regulation±1% 
Voltage distortion≤5%≤10%Full RCD load
≤3%Full R load
DC offset≤200mV 
Transient response≤9%R load 
0%~100%~0%
 ≤6%R load 20%
~100%~20%
Transient recovery≤60ms voltage recovery to 90%Full RCD load
Bypass output 
before turn-on
YES 
Crest ration3:1 
Output frequency range
Normal mode1,Same as input frequency(46Hz~54Hz)
2,50Hz(Input frequency>54Hz or Input frequency<46Hz)
 
Battery mode(50±0.1) Hz 
Slew rate1 Hz/Sec 
Efficiency
Normal  mode> 93%> 90% 
Battery mode> 90%> 90% 
Overload
Normal mode
battery mode 
Overload warning only105%±5%≤load
1min,then transfer to bypass and alarm.105%±5%<
load≤125%±5%
30S,then transfer to bypass and alarm.125%±5%<
load≤150%±5%
300mS, then transfer to bypass and alarm.load>150%±5%
Automatically
 retransfer
YES 
Short protection
Normal
battery mode
YES 
Transfer time
Normal to 
battery mode
0mS 
Battery to 
normal mode
0mS 
Normal to 
bypass mode
<4mS0mS 
Bypass to 
normal mode
<4mS0mS 
Battery and charger
Battery
Rated voltage192VDC240VDC192VDC*2192VDC*2480VDC 
Type/Rating      
Battery 
quantity
162016*216*240 
Backup time      
Protection
Low alarm voltage 
comeback voltage
(180.8V±4V)/ (188.8V±4V)(226V±4V)/ (236V±4V)(180.8V±4V)
(188.8V±4V)
(226V±4V)/ (236V±4V)(452V±4V)
(472V±4V)
33Q 30KL 
use two 
Shutdown voltage
comeback voltage
160V±4V/
168V±4V
(200V±4V)/ (210V±4V)160V±4V/
168V±4V
(200V±4V)/ (210V±4V)(400V±4V)
(420V±4V)
 
DC protection
Overcharge 
protection
comeback voltage
(249.6V±4V)
(216V±4V)
(312V±4V) (270V±4V)(249.6V±4V)
(216V±4V)
(312V±4V) (270V±4V)(624V±4V) 
(540V±4V)
 
Leakage current< 500uA 
Over 
discharge
 protection
14.5h Could be 
set by software
Battery test
Battery weakYES 
Battery faultYES 
Charger
Output voltage(219.2±3)VDC(277±3)VDC(219.2±3)VDC(277±3)VDC(554±3)VDC 
Charge timeDepends on the external battery capacity 
Charge current7.5A6A5A4A10A 
Interface
Alarm silenceYES 
DC power 
turn-on
YES 
Automatically
 retransfer
YES 
Audio alarm
Battery modeBeep/4s 
Battery low
charger fault
Beep/1s 
UPS faultContinue beep 
OverloadBeep/1s 
Bypass modeBeep/2Min 
L/N inverseBeep/2Min 
Communication
RS232 interfaceYES 
Intelligent slotYES 
Monitor softwareAppending with UPS 
Cooling
Force air cooling 
Display
LCD/LED displays UPS status
Environment
Work 
temperature
0ºC~40ºC 
Altitude<1000m 
Audible
 noise
≤60dB 
Storage 
temperature
-15ºC~45ºC 
Work humidity20%~95% 
Standard
EMS
ESDIEC61000-4-2Level4
RSIEC61000-4-3Level3
EFTIEC61000-4-4Level4
SurgeIEC61000-4-5Level4
EMI
ConductedEN55022Class A
RadiatedEN55022Class A
Safety
SafetyGB4943-2001/IEC62040-1 
Machinery features
Size
Outline dimension and net weight
L*W*H (mm)710*260*717840*515*1135 
Net weight(Kg)45/9350/98  195208 
Optional functions
60Hz  OptionalSet by software
Converter mode  OptionalSet by software
ECOOptionalOptionalAvailable and 
set by software
EPOOptionalOptional 
LCD displayOptional  

3 X 400 VAC High Reliability Online High Frequency UPS
 

Send your message to this supplier

*From:
*To:
avatar Ms. Nancy
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now