3 Phase Low Frequency Online UPS 10K-200kVA with External Battery for Hospital Medical Equipments

Phase: Three Phase
Type: On-line
Protection: Short Circuit
Application: Industry
Classification: Lighting/Power
Standby Time: Long-acting Machine
Samples:
US$ 900/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
Legend Strar Series LS33 10K-200K
Standby UPS
Sine Wave Output UPS
Output Capacity
Large Type
Equipment Mode
Decentralized
Brand
Upsen
Nominal Voltage
3 X 380VAC/400VAC
Frequency
46-54Hz or 56-64Hz
Voltage
3 X 380VAC/400VAC
Transfer Time
Zero
Transport Package
Carton/Pallet
Specification
CE & ISO Certificate
Trademark
UPSEN
Origin
China
HS Code
8504402000
Production Capacity
50000 PCS/Mounth

Product Description

Product Description

Double Conversion Online UPS with Long Backup time and Generator compatible

Key Features
1: Humanized display interface
2: DSP technology guarantees high reliability
3: True online double conversion, equipped with IGBT and output transformer
4: Charging/rectifier/inverter fully digital control technology
5: Intelligent control of multiple CPU
6: Accept dual-mains input
7: Parallel operation with up to 4 units (option)
8: Variety of communication options available
9: Intelligent battery management to prolong battery lifecycle
10: Redundant fan design and independent ventilation enhance durable operation under harsh environment
11: Good after-sale services
  

Low Frequency Online UPS Legend Strar Series LS33 10K-200K(3Ph in/3Ph out)

 

Key Features:

  • Online double-conversion.
  • DSP technology guarantees high reliability.
  • True galvanic isolation transformer design.
  • Control designed to withstand all kinds of loads.
  • Intelligent battery management to prolong battery lifecycle.
  • Redundant fan design and independent ventilation enhance durable operation under harsh environment.
  • Adjustable battery numbers.
  • Accept dual-mains input.
  • Parallel operation with up to 4 units (option).
  • Variety of communication options available.

 

Application:

  • Data center, Industrial equipment, Financial and Securities, Large Data rooms, Postal and Telecommunications, Energy and Electricity, Industrial and Commercial tax affair,Medical and Health.

TECHNICAL SPECIFICATION
MODEL LS33 10K LS33 20K LS33 30K LS33  40K LS33 60K LS33 80K LS33 100K LS33 120K LS33 160K LS33  200K
CAPACITY 10KVA /8KW 20KVA /16KW 30KVA /24KW 40KVA /32KW 60KVA /48KW 80KVA /64KW 100KVA /80KW 120KVA /96KW 160KVA /128KW 200KVA /160KW
INPUT
Nominal Voltage 3 x 380VAC/400VAC (3Ph + N)
Acceptable Voltage Range 305VAC ~ 460VAC
Frequency 46-54Hz or 56-64Hz
INVERTER
Nominal Voltage 3 * 380VAC/400VAC (3Ph + N)
Precision Stationary: ±1%
Transitory: ±5% (load variations 100-0-100%)
Frequency 50/60 Hz synchronised ±1 % With mains absent ±0.1 Hz
Max. Synchronisation Speed ±1 Hz/s
Waveform Pure Sinewave
Total Harmonic Distortion (THDv) <2% (Linear Load)
<5% (Non-linear Load)
Phase Displacement 120o ±1% (balanced load)
120o ±2% (imbalances 50% of the load)
Dynamic Recovery Time 1 cycle at 98 % of the static value
Admissible Overload 110% for 10min; 150% for 60sec ; >160% for 200ms
Admissible Crest Factor 3:01
Admissible Power Factor 0.6~1 (inductive or capacitive)
Imbalance Output Voltage @ 100% Unbalanced Load <1%
Current Limit High overload, short-circuit: RMS Voltage Limit
High Crest-Factor current: Peak Voltage Limit
STATIC BYPASS
Type Solid state
Voltage 3 x 380VAC/400VAC (3Ph + N)
Frequency 50/60 Hz
Activation Criterion Microprocessor control
Transfer Time Zero
Admissible Overload 150% for 1 hour; 180% for 30sec; >200% for 200ms
Transfer to Bypass Immediate, for overloads above 160%
Retransfer Automatic after alarm clear
MAINTENANCE BYPASS
Type Without interruption
Voltage 3 * 400V (3Ph + N)
Frequency 50/60 Hz
Overall Efficiency Line Mode 90% 91% 92% 93%
Battery Mode 90% 91% 93% 93%
BATTERY & CHARGER
Battery Type and Numbers 12VDC* 16 pcs 12VDC * 32 pcs (29~32 pcs adjustable)
Nominal Battery Voltage 192 VDC 384 VDC (Based on 32pcs batteries)
Charging Method CC/CV
Precision ±1%
Charging Current Max.: 40 A
Charging Voltage 216 VDC 432 VDC (Based on 32pcs batteries)
PHYSICAL
Dimensions, D*W*H(mm) 656*405* 817 656*405* 941 840*432*1140 975 *554 *1286 1200 *910 *1680 1500 *1140 *1800
Net Weight (Kgs) 180 205 295 330 451 519 950 1350
* Product specifications are subject to change without further notice

DETAIL IMAGES
3 Phase Low Frequency Online UPS 10K-200kVA with External Battery for Hospital Medical Equipments3 Phase Low Frequency Online UPS 10K-200kVA with External Battery for Hospital Medical Equipments3 Phase Low Frequency Online UPS 10K-200kVA with External Battery for Hospital Medical Equipments3 Phase Low Frequency Online UPS 10K-200kVA with External Battery for Hospital Medical Equipments
 
3 Phase Low Frequency Online UPS 10K-200kVA with External Battery for Hospital Medical Equipments
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now