Uninterrupted Power Supply, 3phase Online UPS, Power Supply manufacturer / supplier in China, offering Uninterruptible Power Supply 3phase Online UPS for Medical Instruments, 120/220/230/240VAC Low Frequency Pure Sine Wave Inverters with Charger, Home Use 12/24/48V DC to 220V AC Smart Power Inverter and so on.

(/ )

Supplier Homepage Product High Frequency Online UPS Tower Online UPS Uninterruptible Power Supply 3phase Online UPS for Medical Instruments

Uninterruptible Power Supply 3phase Online UPS for Medical Instruments

FOB Price: US $1-1,000 / Piece
Min. Order: 5 Pieces
Min. Order FOB Price
5 Pieces US $1-1,000/ Piece
Get Latest Price
Port: Shenzhen, China
Production Capacity: 50, 000PCS/Month
Payment Terms: L/C, T/T, Western Union, Money Gram

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: Queen Star Plus 33Q10K-80K
  • Type: On-line
  • Application: Fire Safety
  • Standby Time: Standard Machine
  • Output Capacity: Large Type
  • Brand: Upsen
  • Voltage Precision: Voltage Precision
  • Thdi: Less 5%
  • Transport Package: Cartons & Wooden Pallet
  • Origin: China
  • Phase: Three Phase
  • Protection: Short Circuit
  • Classification: Lighting/Power
  • Standby UPS: Sine Wave Output UPS
  • Equipment Mode: Decentralized
  • Frequency Tracking Rate: Less 1Hz/S
  • Input Connection: 3 Phase +N+PE
  • Trademark: UPSEN
  • Specification: CE & ISO Certificate
  • HS Code: 8504402000
Product Description
Uninterruptible Power Supply 3phase online ups for Medical Instruments
High Frequency Online UPS Queen Star Plus Strar Series 33Q10K-80K(3Ph in/3Ph out)
 
Key Features:
1:Smart RS232 communication interface.
2:UPS with Intelligent battery management (ABM).
3:Intelligent management of battery charging and discharging.
4:Sine-wave output: True sine-wave output with less than 3% THD
5:3 Phase Input/Output for both 190/208/220Vac and 380/400/415Vac.
6:wide input range which is suitable for very unstable power supply situation.
7:Fully digital control with three DSPs including IGBT rectifier, inverter, charger.
8:Support battery cold start and mains supply self-stating, satisfy the user's requirement.
9:Complete isolation design between fragile components and air flue, improving the system reliability greatly.
 
UPS Application
Internet Data Center, Medium-scale network system ,Industrial automatic equipment,Data processing systems, bank  Emergency lighting systems,medical instruments,Medium-scale office automation, precision equipment,etc. 

Technical Specification
 
Technical Specification:
Index33Q 10KL33Q 20KL33Q 30KL33Q 40KL 33Q 60KL 33Q 80KLComments
Input
Input voltage
Rated voltage380VAC/220VAC380VAC 
Phasethree phase with ground 
Turn on 
voltage range
(120±5~274±5)VAC(207±9~475±9)
VAC
 
Bypass 
voltage range
(60±5~300±5)VAC(105±9~518±9)
VAC
Could be 
adjusted 
by software.
Bypass 
low loss
60VAC~220VAC(default 60VAC)105VAC~380VAC
(default 105VAC)
 
Bypass
 low comeback
Low loss +5VACLow loss 
+17VAC
 
Bypass 
high loss
220VAC~300VAC(default 300VAC)380VAC~475VAC
(default 475VAC)
 
Bypass 
high comeback
High loss -5VACHigh loss -17VAC 
Line low loss
comeback
(120±5) VAC /(140±5) VAC(207±9) VAC 
(242±9) VAC
load≤50%
(140±5) VAC /(160±5) VAC(242±9) VAC
(276±9) VAC
50%≤90%
(160±5) VAC /(175±5) VAC(276±9) VAC
(302±9) VAC
load>90%
Line high loss
comeback
(275±5)VAC/(260±5)VAC(475±9)VAC
(449±9)VAC
 
Input frequency
Rated 
frequency
50Hz 
Frequency 
low loss
(40~49) ±0.2Hz(default:46Hz)Could be 
adjusted
 by software.
Frequency 
low comeback
Frequency low loss +0.5Hz
Frequency 
high loss
(51~60)±0.2Hz(default:54Hz)
Frequency 
high comeback
Frequency high loss -0.5Hz
Input power factor
Could be 
adjusted 
by software.
> 0.9933Q 10-40KL:
220VAC,full R load
33Q 60-80KL: 
380VAC,full R load
Generator Support generator inputGenerator rating
≥2*UPS rating
Input current
Rated current 14A28A42A67A80A105A 
Input THDI<= 10% 
Output protection
Rating 
protection
32A 
Breaker
50A 
Breaker
60A 
Breaker
80A 
Breaker
100A 
Breaker
125A 
Breaker
 
Output power
VA/watt10KVA/8KW20KVA/16KW30KVA/24KW40KVA/32KW60KVA/
48KW
80KVA/
64KW
 
Rated voltage220VAC380VACSine wave
Voltage range200/208/220
/230/240VAC
345/359/380
/397/415 VAC
33Q 10-40KL: 
Could be 
adjusted 
by software. 
10% derating 
for 
208VAC
/200VAC.
33Q 60-80KL: 
Could be 
adjusted 
by software. 
10% derating 
for 345VAC
/359VAC.
Voltage regulation±1% 
Voltage distortion≤5%≤10%Full RCD load
≤3%Full R load
DC offset≤200mV 
Transient response≤9%R load 
0%~100%~0%
 ≤6%R load 20%
~100%~20%
Transient recovery≤60ms voltage recovery to 90%Full RCD load
Bypass output 
before turn-on
YES 
Crest ration3:1 
Output frequency range
Normal mode1,Same as input frequency(46Hz~54Hz)
2,50Hz(Input frequency>54Hz or Input frequency<46Hz)
 
Battery mode(50±0.1) Hz 
Slew rate1 Hz/Sec 
Efficiency
Normal  mode> 93%> 90% 
Battery mode> 90%> 90% 
Overload
Normal mode
battery mode 
Overload warning only105%±5%≤load
1min,then transfer to bypass and alarm.105%±5%<
load≤125%±5%
30S,then transfer to bypass and alarm.125%±5%<
load≤150%±5%
300mS, then transfer to bypass and alarm.load>150%±5%
Automatically
 retransfer
YES 
Short protection
Normal
battery mode
YES 
Transfer time
Normal to 
battery mode
0mS 
Battery to 
normal mode
0mS 
Normal to 
bypass mode
<4mS0mS 
Bypass to 
normal mode
<4mS0mS 
Battery and charger
Battery
Rated voltage192VDC240VDC192VDC*2192VDC*2480VDC 
Type/Rating      
Battery 
quantity
162016*216*240 
Backup time      
Protection
Low alarm voltage 
comeback voltage
(180.8V±4V)/ (188.8V±4V)(226V±4V)/ (236V±4V)(180.8V±4V)
(188.8V±4V)
(226V±4V)/ (236V±4V)(452V±4V)
(472V±4V)
33Q 30KL 
use two 
Shutdown voltage
comeback voltage
160V±4V/
168V±4V
(200V±4V)/ (210V±4V)160V±4V/
168V±4V
(200V±4V)/ (210V±4V)(400V±4V)
(420V±4V)
 
DC protection
Overcharge 
protection
comeback voltage
(249.6V±4V)
(216V±4V)
(312V±4V) (270V±4V)(249.6V±4V)
(216V±4V)
(312V±4V) (270V±4V)(624V±4V) 
(540V±4V)
 
Leakage current< 500uA 
Over 
discharge
 protection
14.5h Could be 
set by software
Battery test
Battery weakYES 
Battery faultYES 
Charger
Output voltage(219.2±3)VDC(277±3)VDC(219.2±3)VDC(277±3)VDC(554±3)VDC 
Charge timeDepends on the external battery capacity 
Charge current7.5A6A5A4A10A 
Interface
Alarm silenceYES 
DC power 
turn-on
YES 
Automatically
 retransfer
YES 
Audio alarm
Battery modeBeep/4s 
Battery low
charger fault
Beep/1s 
UPS faultContinue beep 
OverloadBeep/1s 
Bypass modeBeep/2Min 
L/N inverseBeep/2Min 
Communication
RS232 interfaceYES 
Intelligent slotYES 
Monitor softwareAppending with UPS 
Cooling
Force air cooling 
Display
LCD/LED displays UPS status
Environment
Work 
temperature
0ºC~40ºC 
Altitude<1000m 
Audible
 noise
≤60dB 
Storage 
temperature
-15ºC~45ºC 
Work humidity20%~95% 
Standard
EMS
ESDIEC61000-4-2Level4
RSIEC61000-4-3Level3
EFTIEC61000-4-4Level4
SurgeIEC61000-4-5Level4
EMI
ConductedEN55022Class A
RadiatedEN55022Class A
Safety
SafetyGB4943-2001/IEC62040-1 
Machinery features
Size
Outline dimension and net weight
L*W*H (mm)710*260*717840*515*1135 
Net weight(Kg)45/9350/98  195208 
Optional functions
60Hz  OptionalSet by software
Converter mode  OptionalSet by software
ECOOptionalOptionalAvailable and 
set by software
EPOOptionalOptional 
LCD displayOptional  

Uninterruptible Power Supply 3phase Online UPS for Medical Instruments
Uninterruptible Power Supply 3phase Online UPS for Medical Instruments
 
Send your message to this supplier
Avatar
Ms. Nancy
*From:
To: Ms. Nancy
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now