• 3/3 Phase 0.9PF Low Frequency Online UPS Power 10kVA - 400kVA for Industry, Telecom, Communication, Hospital Equipents Use.
  • 3/3 Phase 0.9PF Low Frequency Online UPS Power 10kVA - 400kVA for Industry, Telecom, Communication, Hospital Equipents Use.
  • 3/3 Phase 0.9PF Low Frequency Online UPS Power 10kVA - 400kVA for Industry, Telecom, Communication, Hospital Equipents Use.
  • 3/3 Phase 0.9PF Low Frequency Online UPS Power 10kVA - 400kVA for Industry, Telecom, Communication, Hospital Equipents Use.
  • 3/3 Phase 0.9PF Low Frequency Online UPS Power 10kVA - 400kVA for Industry, Telecom, Communication, Hospital Equipents Use.

3/3 Phase 0.9PF Low Frequency Online UPS Power 10kVA - 400kVA for Industry, Telecom, Communication, Hospital Equipents Use.

Phase: Three Phase
Type: On-line
Protection: Short Circuit
Application: Industry
Classification: Lighting/Power
Standby Time: Long-acting Machine
Customization:
Diamond Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
LF33 Strar Series 10K - 400Kva
Standby UPS
Sine Wave Output UPS
Output Capacity
Large Type
Equipment Mode
Both
Brand
Upsen
Transport Package
Carton/Pallet
Specification
CE & ISO Certificate
Trademark
UPSEN
Origin
China
HS Code
8504402000
Production Capacity
2000PCS/Month

Product Description

Big UPS Industry UPS Telecom UPS Low Frequency 3 Phase UPS System 200K-600Kva
1: Big UPS with Three Phase 380/400/415Vac or 190/208/220Vac Input/Output
2: Low Frequency UPS can be used for data center, industrial process,ATM,Bank,Hospital Equipments and other mission-critical equipments
2: Digital LCD Touch Screen for UPS Operation
3: EPO function for UPS
 

Low Frequency Online UPS Low Frequency Strar Series LF33 10K-400K(3Ph in/3Ph out)

Key Features

1: Use advanced 6th generation DSP and full digital control technologies to realize higher system stability.
2: Output power factor is 0.9, carrying capacity than conventional UPS with 10% above, as users reduce investment cost.
3: Advanced distributed active parallel technology can realize parallel operation of 6PCS UPS units without the need of centralized bypass cabinet.
4: 6-inch extra large LCD that can display 12 language (Chines,English,Russian,Spanish,French and so on).
5: Extra wide input voltage and frequency range make it adapt to severe power grid environment.
6: Intelligent battery management maintains battery automatically to prolong the battery life.
7: Standard input/output filter improves the system EMC performance.
8: Extra strong capability to withstand output overload and short circuit, ensuring the system stability and system safety under extreme conditions.
9: 
Layered independently-sealed ventilation channel and re-dundant fan, circuit boards with protective paints and a dust filter embedded make it highly efficient to dissipate heat and protect the product effectively under severe environment.

Application
Mainly used in large IDC rooms, bank/securities settlement center, communication network management center, semiconductor product lines and large automation production and its control system. According to the special needs of users was improved, and used in large sports venues, conference room, theater and highway and railway tunnels metal halide lamp lighting system.

 

Model LF33 Series
Rectifier Type 6p 12p 6p 12p 6p 12p 6p 12p 6p 12p 12P 12P 12P
Rated Nominal 10KVA/9KW 20KVA/18KVA 30KVA/27KW 40KVA/36KW 60KVA/54KW 80KVA/72KW 100KVA/90KW 120KVA/108KW
Rated input voltage 380/400/415VAC   3-phase 4-wire
Rated frequency 50/60HZ
Input  parameters
Input voltage range ±25%
Input frequency range 45Hz~65Hz
Input soft start function 0-100%    5-300settable
Input power factor >0.8
Input harmonic current <20%
Bypass
Bypass voltage range -20%~+15%
Bypass frequency range 50/60HZ±10%
Output parameters
Inverter output voltage 380/400/415VAC  3-phase 4-wire
Voltage stability ±1%(Steady  status),±3%(Transient  status)
Frequency 50/60Hz
Mains power synchronization window ±5%
Actually measured frequency accuracy (internal clock) 50/60Hz±0.05Hz
Output power factor 0.9(Output 90kW per 100kVA)
Transient response time <5ms
Inverter overload capability At 0.9 power factor, 110% for 1 hour, 125% for 10 minutes  and 150% for   60s
Short circuit current from inverter 3ph 1.5ln for 5seconds,1ph 2.9ln for   5seconds
DC Voltage 360/384/432/480VDC
Maximum Bypasscapability 1000% for 100ms
Phase shift Characteristic With 100% balanced load <1°
With 100% imbalance load <1°
Total harmonic Distortion (THDv) 100% linear load <1%
100% non- linear load <3%
System  efficiency (full Up to 94% (inverter efficiency is up to  98%)
Rectifier output parameters
Charger output voltage stability 1%
DC ripple voltage ≤1%
Operating environment
Operating temperature range 0~40°C
Storage  temperature -25~70°C(Without battery)
Relative humidity 0~95%  No condensation
Maximum operating height ≤Elevation 1000m, for elevation above 1000m, derate by 1% for every increase of  100m
Noise (1m) 58-68dB
Protection level IP20
Standard Safety: IEC60950-1 IEC62040-1-1 UL1778 EMC IEC62040-2 CLASS C2 EN50091-2 CLASS A Design and Test IEC62040-3
Physical parameters
Weight (kg) 980 1420 1200 1750 1350 2000 1600 2200 2100 2750 3690 6390 7390
Width(mm) 900 1250 1250 1640 1250 1640 1640 2280 2280 2280 2835 3955 3955
Depth (mm) 855 855 855 855 855 855 855 855 855 855 1000 1090 1090
Height (mm) 1900 1900 1900 1900 1900 1900 1900 1900 1900 1900 1950 1950 1950
* Product specifications are subject to change without further notice
Model HE33 200-400K
Rectifier Type 6p 12p 6p 12p 6p 12p 6p 12p 6p 12p
Rated Nominal 120KVA/108KW 160KVA/144KVA 200KVA/180KW 300KVA/270KW 400KVA/360KW
Rated input voltage 380/400/415VAC 3-phase 4-wire
Rated frequency 50/60HZ
Input parameters 
Input voltage range ±25%
Input frequency range 45Hz~65Hz
Input soft start function 0-100%   5-300settable
Input power factor >0.98(If harmonic filter is added)
Input harmonic current (THDi) 4.5%(If harmonic filter is added) 
Bypass 
Bypass voltage range -20%~+15%
Bypass frequency range 50/60HZ±10%
Output parameters 
Inverter output voltage 380/400/415VAC 3-phase 4-wire
Voltage stability ±1%(Steady status),±3%(Transient status)
Frequency 50/60Hz
Mains power synchronization window ±5%
Actually measured frequency accuracy (internal clock) 50/60Hz±0.01Hz
Output power factor 0.9(Output 90kW per 100kVA)
Transient response time <5ms
Inverter overload capability At 0.9 power factor, 110% for 1 hour, 125% for 10 minutes and 150% for 60s
Short circuit current from inverter 3ph 1.5ln for 5seconds,1ph 2.9ln for 5seconds
Maximum Bypass capability 1000% for 100ms
Phase shift characteristic With 100% balanced load <1°
With 100% imbalance load <1°
Total harmonic
Distortion(THDv)
100% linear load <1%
100% non-linear load <3%
System efficiency (full load) Up to 94% (inverter efficiency is up to 98%)
Rectifier output parameters
Charger output voltage stability 1%
DC ripple voltage ≤1%
Operating environment 
Operating temperature range 0~40°C
Storage temperature -25~70°C(Without battery)
Relative humidity 0~95% No condensation
Noise (1m) 58-68dB
Protection level IP20
Standard Safety: IEC60950-1 IEC62040-1-1 UL1778 EMC IEC62040-2 CLASS C2 EN50091-2 CLASS A Design and Test IEC62040-3
*Specification changes without further notice
3/3 Phase 0.9PF Low Frequency Online UPS Power 10kVA - 400kVA for Industry, Telecom, Communication, Hospital Equipents Use.
3/3 Phase 0.9PF Low Frequency Online UPS Power 10kVA - 400kVA for Industry, Telecom, Communication, Hospital Equipents Use.
3/3 Phase 0.9PF Low Frequency Online UPS Power 10kVA - 400kVA for Industry, Telecom, Communication, Hospital Equipents Use.


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

Find Similar Products By Category

Supplier Homepage Products Low Frequency Online UPS 3/3 Phase 0.9PF Low Frequency Online UPS Power 10kVA - 400kVA for Industry, Telecom, Communication, Hospital Equipents Use.