Pure Sine Wave Rack Mounted UPS for network devices
Model:Rack Mount Star Series 1K-10KVA
Key Features:
1)Intelligent slot available
2)excellent electrical performance
3)Wide input voltage range, Zero transfer time
4)Fan speed auto control when loads varies
5)Protection against all types of power problems
6)Auto Self-Testing System whileTurning on UPS
7)Humanization bypass output, can be adjustable.
8)Provide intelligent slot, Provide standard battery pack
9)Smart RS232 communication with monitoring software
10)Input L and N lines reverse wiring detection, Auto start when AC back.
11)the user can easily get UPS status information, including the working mode
12)LED/LCD Indicators display Detailed Real-Time UPS Status and parameters.
13)Set Output Voltage, Frequency parameter and bypass function on the display.
Applications
RM Series 1KVA~10KVA High Frequency Rack Mount Online UPS is specially designed for
servers, Data-center, critical network devices, Sensitive electronic equipment, Telecom,Transmission equipment,,communication,public security, ATM etc.
Technical Specification
Model |
RM1K |
RM2K |
RM3K |
RM1KL |
RM2KL |
RM3KL |
RM6KL |
RM10KL |
Rated Power |
VA/W |
1Kva/ 0.8Kw |
2Kva/ 1.6kw |
3Kva/ 2.4Kw |
1Kva/ 0.8Kw |
2Kva/ 1.6Kw |
3Kva/ 2.4Kw |
6Kva/ 4.8Kw |
10Kva/ 8Kw |
Input |
Phase |
Single Phase with Ground |
Nominal Voltage |
110115//120Vac or 220/230/240Vac |
220/230/240Vac |
Voltage Range |
60-138VAC or 115 ~ 300VAC |
176 ~ 276VAC |
Frequency Range |
46 ~ 54Hz(default), user adjustable within 40~60Hz |
46 ~ 54Hz |
Power Factor |
0.97 |
0.98 |
Connection |
IEC320-10A inlet |
IEC320-16A inlet |
IEC320-10A inlet |
IEC320-16A inlet |
Terminal Block |
Output |
Phase |
Single Phase |
Voltage |
110/115/120Vac or 220/230/240VAC ± 2% |
110/115/120Vac or 220/230/240VAC± 1% |
Frequency |
46~54Hz or 50Hz ± 0.2Hz (Line mode) |
46~54Hz (Line mode) |
50Hz ± 0.2Hz ( Battery mode) |
50Hz ± 0.05Hz ( Battery mode) |
Waveform |
Pure Sine Wave |
Overload Capability |
108%~150% for 30 sec., 150% for 300 ms |
105%~130% for 10 min.,130% for 1 min. |
Current Crest Ratio |
3:01 |
Connections |
IEC320 - 10A * 4 |
IEC320-10A and Terminal Block |
IEC320 - 10A * 4 |
IEC320-10A and Terminal Block |
IEC320-10A * 4 and Terminal Block |
Bypass |
Auto Transfer |
on overload and UPS failure |
Before UPS Power-on |
Default "NO", user adjustable to "YES" |
Yes |
Voltage Rangee |
80~264VAC (Default), user adjustable within 80~286VAC |
176 ~ 261VAC |
Transfer Time |
0 ms; less than 4 ms from inverter to bypass and vice versa |
Zero |
LED&LCD indicators |
Load level / Battery level, Battery , Utility Power, Inverter, Bypass, Overload, Fault |
Audible Alarm |
Bypass, On battery mode, Battery low, Overload, Fault |
Communications |
RS-232 Serial Interface |
Intelligent Slot; |
OPTIONS: WEBPOWER SNMP/WEB card, AS400 card or WinPower CMC) |
Network Surge Protection |
RJ45 I/O port available for network or Fax/Modem |
Environmental |
Operating Temperature |
0 ~ 40°C |
Operating Humidity |
20 ~ 90% non-condensing |
Main Unit |
Net Weight (Kg) |
16.3 |
10.3 |
11.2 |
9.1 |
11.5 |
12.3 |
18.3 |
20.3 |
Dimensions (W x D x H) mm |
482 x 420 x 88 (2U) |
482 x 420 x 88 (2U) or (3U Internal Batteries |
482 x 420 x 88 (2U) |
482.6 x 600 x 130 (3U) Optional 4U |
Battery Pack |
Type |
Internal Batteries |
|
Nominal DC Voltage |
24/36VDC |
72/96VDC |
24/36VDC |
72/96VDC |
192/240VDC |
Battery Numbers & Capacity |
2/3Pcs *12V9Ah |
6/8Pcs*12V7.2Ah |
Depending on the capacity of external battery packs |
Backup Time (Full load) |
5min |
9min (with 1 BP) |
5min (With 1BP) |
Recharge Time |
5hrs to 90% |
Charging Current (Max.) |
1.0A |
8A±1A |
4.2A |
Charging Voltage |
27.4/41.1Vdc±0.6V |
110Vdc±0.4V |
41.1Vdc±0.6V |
110Vdc±0.4V |
274Vdc±1%V |
Net Weight (Kg) |
--- |
25.3 |
25.3 |
--- |
--- |
--- |
--- |
Dimensions (W x D x H) mm |
--- |
482 x 420 x88(2U) |
--- |
--- |
--- |
--- |
*Specification are subject to change without prior notice |